Department of Radiology, Vanderbilt University Institute of Imaging Science, Nashville, TN 37232, USA.
Proc Natl Acad Sci U S A. 2013 Aug 27;110(35):14150-5. doi: 10.1073/pnas.1306586110. Epub 2013 Aug 14.
The exquisite NMR spectral sensitivity and negligible reactivity of hyperpolarized xenon-129 (HP(129)Xe) make it attractive for a number of magnetic resonance applications; moreover, HP(129)Xe embodies an alternative to rare and nonrenewable (3)He. However, the ability to reliably and inexpensively produce large quantities of HP(129)Xe with sufficiently high (129)Xe nuclear spin polarization (P(Xe)) remains a significant challenge--particularly at high Xe densities. We present results from our "open-source" large-scale (∼1 L/h) (129)Xe polarizer for clinical, preclinical, and materials NMR and MRI research. Automated and composed mostly of off-the-shelf components, this "hyperpolarizer" is designed to be readily implementable in other laboratories. The device runs with high resonant photon flux (up to 200 W at the Rb D1 line) in the xenon-rich regime (up to 1,800 torr Xe in 500 cc) in either single-batch or stopped-flow mode, negating in part the usual requirement of Xe cryocollection. Excellent agreement is observed among four independent methods used to measure spin polarization. In-cell P(Xe) values of ∼90%, ∼57%, ∼50%, and ∼30% have been measured for Xe loadings of ∼300, ∼500, ∼760, and ∼1,570 torr, respectively. P(Xe) values of ∼41% and ∼28% (with ∼760 and ∼1,545 torr Xe loadings) have been measured after transfer to Tedlar bags and transport to a clinical 3 T scanner for MR imaging, including demonstration of lung MRI with a healthy human subject. Long "in-bag" (129)Xe polarization decay times have been measured (T1 ∼38 min and ∼5.9 h at ∼1.5 mT and 3 T, respectively)--more than sufficient for a variety of applications.
氙-129(HP(129)Xe)具有出色的 NMR 光谱灵敏度和可忽略的反应性,因此它在许多磁共振应用中很有吸引力;此外,HP(129)Xe 是一种替代稀有且不可再生的 (3)He 的选择。然而,能够可靠且经济高效地生产大量具有足够高的氙-129 核自旋极化(P(Xe))的 HP(129)Xe,仍然是一个重大挑战——特别是在高氙气密度下。我们展示了我们的“开源”大规模(∼1 L/h)(129)Xe 极化器在临床、临床前和材料 NMR 和 MRI 研究中的结果。该“极化器”自动化程度高,主要由现成组件组成,旨在便于在其他实验室中实施。该设备在氙气丰富的条件下(在 500 cc 中高达 1,800 托的 Xe)以高共振光子通量(高达 Rb D1 线的 200 W)运行,在单次批次或停止流动模式下,部分否定了通常对 Xe 低温收集的要求。四种独立的测量自旋极化的方法之间观察到极好的一致性。对于分别约为 300、500、760 和 1,570 托的 Xe 负载,测量到的腔内 P(Xe)值分别约为 90%、57%、50%和 30%。在转移到 Tedlar 袋并运送到临床 3 T 扫描仪进行磁共振成像后,测量到的 P(Xe)值分别约为 41%和 28%(分别带有约 760 和 1,545 托的 Xe 负载),包括对健康人体的肺部 MRI 的演示。已经测量了长“袋内”(129)Xe 极化衰减时间(分别在约 1.5 mT 和 3 T 下约为 38 分钟和 5.9 小时)——足以满足各种应用的需求。