Kolibab K, Yang A, Parra M, Derrick S C, Morris S L
Center for Biologics Evaluation and Research, U.S. Food and Drug Administration, Bethesda, Maryland, USA.
Clin Vaccine Immunol. 2014 Mar;21(3):453-5. doi: 10.1128/CVI.00742-13. Epub 2013 Dec 26.
Clinical studies have suggested that the enumeration of mycobacteria by using automated liquid systems is a faster and simpler alternative to quantitative cultures. Here, we show that the time to detection of M. tuberculosis growth as measured with the MGIT 320 liquid culture system inversely correlates with CFU determinations from culture on solid media and that mycobacterial quantification using the MGIT system is faster and easier to perform than CFU plating.