OBJECTIVES

The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL).

MATERIALS AND METHODS

The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions.

RESULTS

Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model.

CONCLUSIONS

Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

摘要

目的

本文旨在通过相关性分析评估先前研究中报道的电阻抗测量比值,以明确其作为电子根尖定位仪(EAL)准确性的影响因素。

材料与方法

使用Medline和Embase筛选有关EAL电学性质测量的文献。将获取的所有数据进行绘图,以确定阻抗与对数标度频率之间的相关性。使用线性斜坡函数拟合评估大多数EAL中用于检测根尖狭窄(APC)的阻抗比值法的准确性。针对各种锉的位置,评估不同频率下阻抗比值的变化。

结果

在检索过程中选出的十篇论文中,对数标度频率与阻抗之间的一阶方程呈负向。当假设比值模型为线性斜坡函数时,如果锉深入,则比值减小,并且在9项研究中的8项中,左右水平区域的平均比值存在显著差异。APC位于线性斜坡模型左右水平区域之间的线性关系区间内。

结论

使用比值法时,APC位于一个线性区间内。因此,使用不同频率下电阻抗测量的阻抗比值是检测APC的可靠方法。