The aim of this study on human cadavers was to compare the accuracy of two electronic apex locators (EALs) Dentaport ZX (J. Morita Corporation, Tokyo, Japan) and Raypex 6 (VDW, Munich, Germany).
Twenty-two single rooted teeth of four human cadaver heads were scheduled for this study. Before the extraction, an access cavity was opened and the crown was cut to establish a stable reference point for all measurements. The working length determination was performed with Dentaport ZX and Raypex 6 in the presence or not of 5.25 % sodium hypochlorite (SH) using a k-file 10. The teeth were then extracted and the real working length (RWL) was measured under a stereomicroscope at ×30 magnification. The difference between the two working lengths was calculated: positive values indicate measurements exceeding the foramen, while negative values indicated measurements short of the foramen. The data were analyzed with a t test analysis.
The mean of distances was 0.33 ± 0.20 mm and 0.32 ± 0.2 mm for Dentaport ZX respectively in the presence or not of SH and 0.38 ± 0.20 mm and 0.39 ± 0.19 mm for Raypex 6. No statistical differences were found between the two devices (p > 0.05).
Both apex locators showed a high accuracy in the presence or not of SH.
Both electronic apex locators can be recommended for clinical use and their accuracy is not affected by SH.
本项针对人体尸体的研究旨在比较两种电子根尖定位仪(EAL)——登特波特ZX(日本东京森田公司)和瑞速6(德国慕尼黑VDW公司)的准确性。
本研究选用了四颗人体尸体头部的22颗单根牙。在拔牙前,开髓并磨除牙冠以建立一个稳定的参考点用于所有测量。使用10号K锉,在有或无5.25%次氯酸钠(SH)的情况下,分别用登特波特ZX和瑞速6测定工作长度。然后将牙齿拔除,并在30倍放大率的体视显微镜下测量实际工作长度(RWL)。计算两种工作长度之间的差值:正值表示测量值超过根尖孔,而负值表示测量值短于根尖孔。采用t检验分析数据。
在有或无SH的情况下,登特波特ZX的平均距离分别为0.33±0.20毫米和0.32±0.2毫米,瑞速6的平均距离分别为0.38±0.20毫米和0.39±0.19毫米。两种仪器之间未发现统计学差异(p>0.05)。
两种根尖定位仪在有或无SH的情况下均显示出较高的准确性。
两种电子根尖定位仪均可推荐用于临床,其准确性不受SH影响。