Dosimetric characteristics of brass mesh as bolus under megavoltage photon irradiation.

作者信息

Richmond Neil D, Daniel Jim M, Whitbourn Joe R, Greenhalgh Andrew D

机构信息

Department of Medical Physics, The James Cook University Hospital, Middlesbrough, UK.

出版信息

Br J Radiol. 2016;89(1059):20150796. doi: 10.1259/bjr.20150796. Epub 2016 Jan 12.

Abstract

OBJECTIVE

This article presents a set of dosimetric measurements describing the properties of brass mesh (Whiting and Davis, Attleboro Falls, MA) under megavoltage photon irradiation conditions, with particular relevance to its use in breast radiotherapy.

METHODS

The effectiveness of brass mesh as a bolus material was investigated using 6-, 15- and 6-MV flattening filter-free photon beams. The effect on dose build-up at the entrance surface, build-down at the beam-exit surface, dose with surface entrance obliquity, beam profiles, penumbra and percentage depth doses were investigated.

RESULTS

One layer of the brass mesh produces a build-up effect equivalent to 1.1 mm of water at 6 MV and 1.9 mm at 15 MV. The brass generates a backscattered component of dose, if the photon beam exits through it. Percentage depth-dose curves are largely unaffected by the mesh and are shown to be equivalent to plain-field data. Beam penumbra and profiles are unchanged by the brass except within the first millimetre (mm) of phantom, where a periodic pattern of dose enhancement is seen.

CONCLUSION

The data presented demonstrate that one layer of brass mesh provides a similar dose build-up effect equivalent to only a few millimetres of water. However, backscatter from the high atomic number (Z) mesh, at the beam exit, contributes appreciably to the overall dose surface enhancement. This dosimetric consequence cannot be neglected and indeed should be considered and accounted for, when determining the bolus effect of the brass mesh in the case of tangential breast irradiation. Advance in knowledge: This article provides dosimetric data necessary for the introduction of brass mesh bolus into the clinical setting for external-beam breast radiotherapy.

摘要

目的

本文介绍了一组剂量测量结果,描述了兆伏级光子辐照条件下黄铜网(位于马萨诸塞州阿特尔伯勒瀑布的怀廷和戴维斯公司生产)的特性,尤其涉及其在乳腺放射治疗中的应用。

方法

使用6兆伏、15兆伏和6兆伏无均整器光子束研究黄铜网作为等效填充物材料的有效性。研究了其对入射表面剂量积累、出射表面剂量衰减、表面入射倾斜时的剂量、射野轮廓、半值层和百分深度剂量的影响。

结果

一层黄铜网在6兆伏时产生的剂量积累效应相当于1.1毫米水,在15兆伏时相当于1.9毫米水。如果光子束从黄铜网穿出,黄铜会产生剂量的反向散射成分。百分深度剂量曲线在很大程度上不受网的影响,且显示与平野数据等效。除了在模体的第一毫米内,黄铜对射野半值层和轮廓没有影响,在模体第一毫米内可看到剂量增强的周期性模式。

结论

所呈现的数据表明,一层黄铜网提供的剂量积累效应与仅几毫米水的效应相似。然而,高原子序数(Z)网在射野出口处的反向散射对总体剂量表面增强有显著贡献。在确定乳腺切线照射时黄铜网的等效填充效应时,这种剂量学后果不可忽视,确实应予以考虑和计入。知识进展:本文提供了将黄铜网等效填充物引入外照射乳腺放射治疗临床应用所需的剂量学数据。