Suppr超能文献

用于肺部肿瘤定位的正交视图相位匹配数字断层合成的临床研究

Clinical Study of Orthogonal-View Phase-Matched Digital Tomosynthesis for Lung Tumor Localization.

作者信息

Zhang You, Ren Lei, Vergalasova Irina, Yin Fang-Fang

机构信息

Medical Physics Graduate Program, Duke University, Durham, NC, USA.

Department of Radiation Oncology, Duke University Medical Center, Durham, NC, USA.

出版信息

Technol Cancer Res Treat. 2017 Dec;16(6):866-878. doi: 10.1177/1533034617705716. Epub 2017 Apr 28.

Abstract

BACKGROUND AND PURPOSE

Compared to cone-beam computed tomography, digital tomosynthesis imaging has the benefits of shorter scanning time, less imaging dose, and better mechanical clearance for tumor localization in radiation therapy. However, for lung tumors, the localization accuracy of the conventional digital tomosynthesis technique is affected by the lack of depth information and the existence of lung tumor motion. This study investigates the clinical feasibility of using an orthogonal-view phase-matched digital tomosynthesis technique to improve the accuracy of lung tumor localization.

MATERIALS AND METHODS

The proposed orthogonal-view phase-matched digital tomosynthesis technique benefits from 2 major features: (1) it acquires orthogonal-view projections to improve the depth information in reconstructed digital tomosynthesis images and (2) it applies respiratory phase-matching to incorporate patient motion information into the synthesized reference digital tomosynthesis sets, which helps to improve the localization accuracy of moving lung tumors. A retrospective study enrolling 14 patients was performed to evaluate the accuracy of the orthogonal-view phase-matched digital tomosynthesis technique. Phantom studies were also performed using an anthropomorphic phantom to investigate the feasibility of using intratreatment aggregated kV and beams' eye view cine MV projections for orthogonal-view phase-matched digital tomosynthesis imaging. The localization accuracy of the orthogonal-view phase-matched digital tomosynthesis technique was compared to that of the single-view digital tomosynthesis techniques and the digital tomosynthesis techniques without phase-matching.

RESULTS

The orthogonal-view phase-matched digital tomosynthesis technique outperforms the other digital tomosynthesis techniques in tumor localization accuracy for both the patient study and the phantom study. For the patient study, the orthogonal-view phase-matched digital tomosynthesis technique localizes the tumor to an average (± standard deviation) error of 1.8 (0.7) mm for a 30° total scan angle. For the phantom study using aggregated kV-MV projections, the orthogonal-view phase-matched digital tomosynthesis localizes the tumor to an average error within 1 mm for varying magnitudes of scan angles.

CONCLUSION

The pilot clinical study shows that the orthogonal-view phase-matched digital tomosynthesis technique enables fast and accurate localization of moving lung tumors.

摘要

背景与目的

与锥形束计算机断层扫描相比,数字断层合成成像具有扫描时间短、成像剂量低以及在放射治疗中对肿瘤定位具有更好的机械间隙等优点。然而,对于肺部肿瘤,传统数字断层合成技术的定位准确性受到深度信息缺失和肺部肿瘤运动的影响。本研究探讨使用正交视图相位匹配数字断层合成技术提高肺部肿瘤定位准确性的临床可行性。

材料与方法

所提出的正交视图相位匹配数字断层合成技术得益于两个主要特征:(1)它获取正交视图投影以改善重建数字断层合成图像中的深度信息;(2)它应用呼吸相位匹配将患者运动信息纳入合成的参考数字断层合成组中,这有助于提高移动肺部肿瘤的定位准确性。进行了一项纳入14例患者的回顾性研究,以评估正交视图相位匹配数字断层合成技术的准确性。还使用拟人化体模进行了体模研究,以探讨在治疗过程中使用kV级聚合投影和射野方向观电影MV投影进行正交视图相位匹配数字断层合成成像的可行性。将正交视图相位匹配数字断层合成技术的定位准确性与单视图数字断层合成技术和无相位匹配的数字断层合成技术进行了比较。

结果

在患者研究和体模研究中,正交视图相位匹配数字断层合成技术在肿瘤定位准确性方面均优于其他数字断层合成技术。对于患者研究,在30°的总扫描角度下,正交视图相位匹配数字断层合成技术将肿瘤定位的平均(±标准差)误差为1.8(0.7)mm。对于使用聚合kV-MV投影的体模研究,对于不同大小的扫描角度,正交视图相位匹配数字断层合成技术将肿瘤定位的平均误差在1mm以内。

结论

初步临床研究表明,正交视图相位匹配数字断层合成技术能够快速、准确地定位移动的肺部肿瘤。