安装时间流量龙头后医院热水管网中嗜肺军团菌定植率。

Rate of Legionella pneumophila colonization in hospital hot water network after time flow taps installation.

机构信息

Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy.

Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy.

出版信息

J Hosp Infect. 2018 Jan;98(1):60-63. doi: 10.1016/j.jhin.2017.08.021. Epub 2017 Sep 7.

Abstract

In hospital water systems legionellae may be resistant to disinfectants in pipework, which is a problem particularly in areas where there is low flow or stagnation of water. We evaluated legionella colonization of a water network of an Italian hospital after time flow taps (TFTs) installation in proximity to dead legs. The water volume flushed was 64 L/day from May 2016, and 192 L/day from December 2016. Before TFTs installation, Legionella pneumophila sg2-14 was detected in all points (4 × 10 ± 3.1 × 10 cfu/L). All sites remained positive (2.9 × 10 ± 1.9 × 10 cfu/L) through November 2016. From December 2016 legionella persisted in one point only (2 × 10 to 6.8 × 10 cfu/L). TFTs with chemical disinfection may reduce legionella colonization associated with dead legs.

摘要

在医院的供水系统中,军团菌可能会对管道中的消毒剂产生抗药性,这在水流较小或水停滞的地方是一个特别的问题。我们在意大利一家医院的水网中安装了接近死水段的时间流量龙头(TFT)后,评估了军团菌的定植情况。从 2016 年 5 月开始,每天冲洗 64 升水,从 2016 年 12 月开始,每天冲洗 192 升水。在安装 TFT 之前,所有点位均检测到嗜肺军团菌 sg2-14(4×10±3.1×10cfu/L)。所有点位在 2016 年 11 月之前一直呈阳性(2.9×10±1.9×10cfu/L)。从 2016 年 12 月开始,军团菌仅在一个点位持续存在(2×10 至 6.8×10cfu/L)。带有化学消毒功能的 TFT 可能会减少与死水段相关的军团菌定植。