左侧或右侧自动体外除颤训练——一项随机模拟研究。

Automated external defibrillation training on the left or the right side - a randomized simulation study.

作者信息

Stærk Mathilde, Bødtker Henrik, Lauridsen Kasper G, Løfgren Bo

机构信息

Research Center for Emergency Medicine, Aarhus University Hospital, Aarhus.

Clinical Research Unit.

出版信息

Open Access Emerg Med. 2017 Sep 14;9:73-79. doi: 10.2147/OAEM.S140220. eCollection 2017.

Abstract

BACKGROUND

Correct placement of the left automated external defibrillator (AED) electrode is rarely achieved. AED electrode placement is predominantly illustrated and trained with the rescuer sitting on the right side of the patient. Placement of the AED electrodes from the left side of the patient may result in a better overview of and access to the left lateral side of the thorax. This study aimed to investigate if training in automated external defibrillation on the left side compared to the right side of a manikin improves left AED electrode placement.

METHODS

Laypeople attending basic life support training were randomized to learn automated external defibrillation from the left or right side of a manikin. After course completion, participants used an AED and placed AED electrodes in a simulated cardiac arrest scenario.

RESULTS

In total, 40 laypersons were randomized to AED training on the left (n=19 [missing data =1], 63% female, mean age: 47.3 years) and right (n=20, 75% female, mean age: 48.7 years) sides of a manikin. There was no difference in left AED electrode placement when trained on the left or right side: the mean (SD) distances to the recommended left AED electrode position were 5.9 (2.1) cm vs 6.9 (2.2) cm (=0.15) and to the recommended right AED electrode position were 2.6 (1.5) cm vs 1.8 (0.8) cm (=0.06), respectively.

CONCLUSION

Training in automated external defibrillation on the left side of a manikin does not improve left AED electrode placement compared to training on the right side.

摘要

背景

很少能正确放置左侧自动体外除颤器(AED)电极。AED电极放置的演示和培训主要是让救援者坐在患者右侧进行。从患者左侧放置AED电极可能会更好地观察和触及胸部左侧。本研究旨在调查与在人体模型右侧进行自动体外除颤训练相比,在左侧进行训练是否能改善左侧AED电极的放置。

方法

参加基础生命支持培训的非专业人员被随机分配,从人体模型的左侧或右侧学习自动体外除颤。课程结束后,参与者使用AED,并在模拟心脏骤停场景中放置AED电极。

结果

总共40名非专业人员被随机分配到在人体模型左侧(n = 19[缺失数据 = 1],63%为女性,平均年龄:47.3岁)和右侧(n = 20,75%为女性,平均年龄:48.7岁)进行AED培训。在左侧或右侧接受训练时,左侧AED电极放置没有差异:到推荐的左侧AED电极位置的平均(标准差)距离分别为5.9(2.1)厘米和6.9(2.2)厘米(P = 0.15),到推荐的右侧AED电极位置的平均(标准差)距离分别为2.6(1.5)厘米和1.8(0.8)厘米(P = 0.06)。

结论

与在人体模型右侧进行训练相比,在左侧进行自动体外除颤训练并不能改善左侧AED电极的放置。