Engel Florian A, Faude Oliver, Kölling Sarah, Kellmann Michael, Donath Lars
Department of Movement and Training Science, Institute of Sport and Sport Science, Heidelberg University, Heidelberg, Germany.
Department of Sport, Exercise and Health, University of Basel, Basel, Switzerland.
Front Physiol. 2019 Apr 25;10:460. doi: 10.3389/fphys.2019.00460. eCollection 2019.
As verbal encouragement (VE) is used in high intensity functional exercise testing, this randomized controlled crossover study aimed at investigating whether VE affects high intensity functional strength and endurance performance testing. We further examined between-day variability of high intensity functional strength and endurance performance testing with and without VE. Nineteen experienced athletes (seven females and 12 males, age: 23.7 ± 4.3 years) performed a standardized one repetition maximum (1 RM) squat test and a 12-min high-intensity functional training (HIFT) workout [as many repetitions as possible (AMRAP)] on four different days over a 2-week period. Athletes randomly performed each test twice, either with VE or without (CON), with a minimum of 72 h rest between tests. Very good to excellent relative between-day reliability with slightly better values for strength testing (ICC: 0.99; CV: 3.5-4.1%) compared to endurance testing (ICC 0.87-0.95; CV: 3.9-7.3%) were observed. Interestingly, VE led to higher reliability during endurance testing. Mean squat strength depicted higher strength values with VE (107 ± 33 kg) compared to CON (105 ± 33 kg; = 0.009, Cohen's d: 0.06). AMRAP in the endurance test showed negligible differences between VE (182 ± 33 AMRAP) and CON (181 ± 35 AMRAP; = 0.71, Cohen's d: 0.03). In conclusion, the effects of VE do not notably exceed day-to-day variability during high intensity functional strength (CV: 3.5-4.1%) and endurance (CV: 3.9-7.3%) testing. However, high intensity functional strength and endurance testing with VE seems to be slightly more reliable, particularly during endurance testing.
由于言语鼓励(VE)用于高强度功能性运动测试,本随机对照交叉研究旨在调查VE是否会影响高强度功能性力量和耐力性能测试。我们进一步研究了有无VE时高强度功能性力量和耐力性能测试的日间变异性。19名有经验的运动员(7名女性和12名男性,年龄:23.7±4.3岁)在2周内的4个不同日子进行了标准化的一次重复最大重量(1 RM)深蹲测试和12分钟的高强度功能性训练(HIFT)锻炼[尽可能多的重复次数(AMRAP)]。运动员随机对每个测试进行两次,一次有VE,一次无VE(对照组),两次测试之间至少休息72小时。观察到日间可靠性非常好到优秀,力量测试的值略高于耐力测试(组内相关系数:0.99;变异系数:3.5 - 4.1%)(耐力测试组内相关系数0.87 - 0.95;变异系数:3.9 - 7.3%)。有趣的是,VE在耐力测试期间导致更高的可靠性。与对照组(105±33千克;P = 0.009,科恩d值:0.06)相比,有VE时平均深蹲力量显示出更高的力量值(107±33千克)。耐力测试中的AMRAP在有VE(182±33次AMRAP)和对照组(181±35次AMRAP;P = 0.71,科恩d值:0.03)之间显示出可忽略不计的差异。总之,在高强度功能性力量(变异系数:3.5 - 4.1%)和耐力(变异系数:3.9 - 7.3%)测试期间,VE的影响并未显著超过每日变异性。然而,有VE时的高强度功能性力量和耐力测试似乎稍微更可靠,特别是在耐力测试期间。