Suppr超能文献

单光子发射计算机断层扫描/计算机断层扫描评估唾液腺功能障碍:最大标准化摄取值诊断能力的初步研究。

Single-photon emission computed tomography/computed tomography for evaluation of salivary gland dysfunction: preliminary study on diagnostic ability of maximum standardized uptake value.

机构信息

Comprehensive Dental Care, The Nippon Dental University Niigata Hospital, Niigata, Japan.

Oral and Maxillofacial Surgery, Dry Mouth Clinic, The Nippon Dental University Niigata Hospital, Niigata, Japan.

出版信息

Oral Radiol. 2020 Apr;36(2):163-167. doi: 10.1007/s11282-019-00393-2. Epub 2019 Jun 14.

Abstract

OBJECTIVES

The aim of this study was to investigate of salivary gland dysfunction with single-photon emission computed tomography/computed tomography (SPECT/CT), especially the relationship between maximum standardized uptake value (SUV) of salivary glands and their dysfunction.

METHODS

Five patients (2 submandibular sialolithiasis, 2 Sjögren's syndrome, and 1 parotitis) who underwent SPECT/CT were included in this study. The salivary gland excretion function was defined as A (pre-stimulatory 20 min after injection of Tc-99m pertechnetate)/B (post-stimulatory 40 min after injection of Tc-99m pertechnetate) using SUV of parotid and submandibular glands.

RESULTS

SUV before stimulation of the submandibular gland with sialoliths in a patient was lower than that in the opposite submandibular gland without sialoliths (5.81 vs 51.37). Furthermore, the A/B using SUV in the other patient of submandibular glands with sialoliths was lower than that in the opposite submandibular glands without sialoliths (0.70 vs 1.85). The A/B using SUV of right and left parotid gland in a patient with Sjögren's syndrome was 1.06 and 0.74, respectively. Furthermore, the A/B using SUV of right and left parotid glands in the other patient with Sjögren's syndrome was 3.20 and 4.32, respectively. The A/B using SUV of right and left parotid glands in a patient with left parotitis was 2.26 and 1.58, respectively.

CONCLUSION

The results of the present study indicate that SUV using SPECT/CT seems a useful tool for evaluation of the salivary gland dysfunction.

摘要

目的

本研究旨在探讨唾液腺功能障碍的单光子发射计算机断层扫描/计算机断层扫描(SPECT/CT)表现,特别是唾液腺最大标准化摄取值(SUV)与其功能障碍的关系。

方法

本研究纳入了 5 名接受 SPECT/CT 检查的患者(2 例下颌下腺涎石症、2 例干燥综合征和 1 例腮腺炎)。使用腮腺和下颌下腺的 SUV 定义唾液腺排泄功能为 A(注射 Tc-99m 过锝酸盐后 20 分钟预刺激)/B(注射 Tc-99m 过锝酸盐后 40 分钟后刺激)。

结果

1 例下颌下腺涎石症患者的下颌下腺刺激前 SUV 低于对侧无涎石症的下颌下腺(5.81 比 51.37)。此外,另 1 例下颌下腺涎石症患者的下颌下腺 A/B 使用 SUV 低于对侧无涎石症的下颌下腺(0.70 比 1.85)。1 例干燥综合征患者的双侧腮腺 A/B 使用 SUV 分别为 1.06 和 0.74。此外,另 1 例干燥综合征患者的双侧腮腺 A/B 使用 SUV 分别为 3.20 和 4.32。1 例左侧腮腺炎患者的双侧腮腺 A/B 使用 SUV 分别为 2.26 和 1.58。

结论

本研究结果表明,SPECT/CT 中的 SUV 似乎是评估唾液腺功能障碍的有用工具。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验