Prospective, randomized, comparative, and controlled study to estimate the association between angle distance and higher-order aberrations (HOAs) with postoperative visual acuity after presbyopia-correcting IOL implantation. Forty-three eyes from 43 patients were included and randomly assigned in two groups for either AT LISA tri 839MP or Acrysof IQ PanOptix IOL implantation. The OPD-Scan III analyzer was utilized to assess the angle distance and higher-order aberration (HOAs). Twenty-three eyes were in the Acrysof IQ PanOptix group and 20 patients in the AT LISA tri 839MP group. The uncorrected distance visual acuity (UDVA) for the PanOptix group was 0.092 ± 0.10, whereas for AT LISA tri was 0.050 ± 0.06 (=0.229). The uncorrected intermediate visual acuity (UIVA) for the PanOptix group was 0.173 ± 0.18, whereas for AT LISA tri, it was 0.182 ± 0.11 (=0.669). Uncorrected near visual acuity (UNVA) was 0.068 ± 0.04 and 0.085 ± 0.07, respectively (=0.221). Also, correlation coefficient between HOAs and the Strehl ratio for each group were -0.768 ( < 0.0001) and -0.863 (=0.0001). Patients implanted with both trifocal IOLs showed excellent postoperative visual performance at all distances at the six-month follow-up visit. No association was found between angle distance and postoperative visual acuity regardless of the angle magnitude or the two trifocal IOLs inner optical diameter. Also, internal aberrations demonstrated a significant inverse correlation with the Strehl ratio for both trifocal IOLs.
一项前瞻性、随机、比较性和对照研究,旨在评估老视矫正型人工晶状体植入术后角度距离与高阶像差(HOAs)与术后视力之间的关联。纳入了43例患者的43只眼,并随机分为两组,分别植入AT LISA tri 839MP或Acrysof IQ PanOptix人工晶状体。使用OPD-Scan III分析仪评估角度距离和高阶像差(HOAs)。Acrysof IQ PanOptix组有23只眼,AT LISA tri 839MP组有20只眼。PanOptix组的未矫正远视力(UDVA)为0.092±0.10,而AT LISA tri组为0.050±0.06(P = 0.229)。PanOptix组的未矫正中视力(UIVA)为0.173±0.18,而AT LISA tri组为0.182±0.11(P = 0.669)。未矫正近视力(UNVA)分别为0.068±0.04和0.085±0.07(P = 0.221)。此外,每组HOAs与斯特列尔比值之间的相关系数分别为-0.768(P < 0.0001)和-0.863(P = 0.0001)。植入两种三焦点人工晶状体的患者在六个月随访时在所有距离均表现出优异的术后视觉性能。无论角度大小或两种三焦点人工晶状体的内部光学直径如何,均未发现角度距离与术后视力之间存在关联。此外,两种三焦点人工晶状体的内部像差与斯特列尔比值均呈显著负相关。