Chirurgie Orthopédique et Traumatologique, Centre Hospitalo-Universitaire de Rennes, 2, Rue Henri-le-Guilloux, 35000 Rennes, France.
Chirurgie Orthopédique et Traumatologique, Centre Hospitalo-Universitaire de Rennes, 2, Rue Henri-le-Guilloux, 35000 Rennes, France.
Orthop Traumatol Surg Res. 2020 Apr;106(2):269-274. doi: 10.1016/j.otsr.2019.10.028. Epub 2020 Mar 10.
Intervertebral implants increase stability and improve results in lumbar interbody fusion (LIF). The aim of the present study was to assess clinical and radiological results of posterior lumbar interbody fusion (PLIF) using a tantalum intervertebral implant without associated interbody bone graft.
A single-center retrospective study included 52 cases of single-level PLIF, using 2 tantalum intervertebral cages, without interbody bone graft: 42 for degenerative disc disease, 10 for isthmic spondylolisthesis. Minimum follow-up was 2 years. Clinical assessment used a visual analog (pain) scale (VAS), the Oswestry Disability Index (ODI) and the Roland Morris (RM) scale. Tantalum osseointegration and intersegment mobility were assessed on static and dynamic X-ray.
Forty-nine patients were included, with a mean 55months' follow-up (range, 25-74months). VAS, ODI and RM scores showed significant improvement at last-follow-up, at 4, 30 and 28 points respectively. There was no mechanical failure on static X-ray; all patients had less than 5° mobility on dynamic X-ray at last follow-up.
PLIF with tantalum intervertebral implant without interbody bone graft provided satisfactory clinical and radiological results at medium-term follow-up. The present findings showed reliable primary stability and osseointegration of the tantalum implant.
IV.
椎间植入物可增加腰椎体间融合术(LIF)的稳定性并改善其效果。本研究的目的是评估使用无椎间骨移植物的钽椎间植入物进行后路腰椎体间融合术(PLIF)的临床和影像学结果。
一项单中心回顾性研究纳入了 52 例单节段 PLIF 病例,使用了 2 个钽椎间笼,无椎间骨移植物:42 例用于退行性椎间盘疾病,10 例用于峡部裂性脊椎滑脱。最小随访时间为 2 年。临床评估采用视觉模拟评分(疼痛)量表(VAS)、Oswestry 功能障碍指数(ODI)和 Roland Morris(RM)量表。静态和动态 X 射线评估钽骨整合和节段间活动度。
49 例患者纳入研究,平均随访时间为 55 个月(范围 25-74 个月)。VAS、ODI 和 RM 评分在最后随访时均显著改善,分别为 4、30 和 28 分。静态 X 射线无机械故障;所有患者在最后随访时动态 X 射线的活动度均小于 5°。
无椎间骨移植物的钽椎间植入物进行 PLIF 可在中期随访中获得满意的临床和影像学结果。本研究结果表明钽植入物具有可靠的初始稳定性和骨整合性。