Kellogg J A, Landis R C, Nussbaum A S, Bankert D A
J Pediatr. 1987 Jul;111(1):18-21. doi: 10.1016/s0022-3476(87)80335-9.
The ability of pediatricians and hospital laboratory personnel to detect group A streptococci in patients with suspected streptococcal pharyngitis was evaluated using the TestPack Strep A and anaerobic culture. Duplicate throat specimens (for similar processing by both the pediatricians and laboratory technologists) were simultaneously collected on rayon-tipped swabs from patients with symptoms of pharyngitis. Each swab was first inoculated to a 5% sheep blood agar plate, then tested for group A streptococcus antigen using the TestPack Strep A according to the manufacturer's instructions. Cultures were incubated anaerobically at 35 degrees C for 2 nights unless positive after 1 night. Group A streptococci were identified using specific antisera. Pediatric office or laboratory cultures from 112 (31.3%) of the 358 patients contained group A streptococci. Of the patients with positive cultures, 96 (85.7%) and 107 (95.5%) were detected by the pediatricians and laboratory, respectively. Respective findings with the TestPack Strep A by the pediatricians and laboratory were sensitivity 68.8% and 74.8%, specificity 94.3% and 95.6%, predictive value of a positive result 81.5% and 87.9%, and predictive value of a negative result 89.2% and 89.9%. Anaerobic culture was significantly more sensitive than the TestPack Strep A for detection of group A streptococci by both the pediatricians (P less than 0.005) and laboratory personnel (P less than 0.05).
采用TestPack A组链球菌检测试剂盒和厌氧培养法,评估儿科医生和医院实验室工作人员对疑似链球菌性咽炎患者检测A组链球菌的能力。从患有咽炎症状的患者身上,用含人造纤维头的拭子同时采集两份咽喉标本(供儿科医生和实验室技术人员进行类似处理)。每支拭子首先接种到5%的羊血琼脂平板上,然后按照TestPack A组链球菌检测试剂盒制造商的说明检测A组链球菌抗原。培养物在35摄氏度下厌氧培养2晚,除非1晚后呈阳性。使用特异性抗血清鉴定A组链球菌。358名患者中,112名(31.3%)的儿科诊所或实验室培养物中含有A组链球菌。在培养结果呈阳性的患者中,儿科医生和实验室分别检测出96名(85.7%)和107名(95.5%)。儿科医生和实验室使用TestPack A组链球菌检测试剂盒的各自结果为:灵敏度分别为68.8%和74.8%,特异性分别为94.3%和95.6%,阳性结果预测值分别为81.5%和87.9%,阴性结果预测值分别为89.2%和89.9%。对于A组链球菌的检测,厌氧培养对儿科医生(P<0.005)和实验室工作人员(P<0.05)而言,均比TestPack A组链球菌检测试剂盒显著更敏感。