Suppr超能文献

比较杜邦隔离器和罗氏血培养瓶用于检测真菌血症的效果。

Comparison of Du Pont Isolator and Roche Septi-Chek for detection of fungemia.

作者信息

Guerra-Romero L, Edson R S, Cockerill F R, Horstmeier C D, Roberts G D

机构信息

Hospital Severo Ochoa, Leganes-Madrid, Spain.

出版信息

J Clin Microbiol. 1987 Sep;25(9):1623-5. doi: 10.1128/jcm.25.9.1623-1625.1987.

Abstract

The rapid detection of fungemia in hospitalized patients is imperative, particularly for those who are immunocompromised. Our laboratory compared the Roche Septi-Chek with the Du Pont Isolator for the recovery of fungi from blood. Of 23,586 matched pairs of blood cultures, 199 were positive. The Isolator detected 178 (89.4%) and the Septi-Chek detected 119 (59.7%) of all positive isolates. The mean recovery time for the Isolator and Septi-Chek was 2.2 and 4.9 days, respectively. The Isolator detected fungemia earlier than the Septi-Chek did and was the only culture system positive in 83% of 53 patients, whereas the Septi-Chek system yielded the same results in only 13% of the patients. The Isolator provides a more rapid and sensitive method for the recovery of fungi from blood.

摘要

快速检测住院患者的真菌血症至关重要,尤其是对于那些免疫功能低下的患者。我们实验室比较了罗氏Septi-Chek和杜邦Isolator从血液中分离真菌的能力。在23586对匹配的血培养样本中,199份呈阳性。Isolator检测出所有阳性分离株中的178株(89.4%),而Septi-Chek检测出119株(59.7%)。Isolator和Septi-Chek的平均恢复时间分别为2.2天和4.9天。Isolator比Septi-Chek更早检测出真菌血症,并且是53例患者中83%唯一呈阳性的培养系统,而Septi-Chek系统在仅13%的患者中得到相同结果。Isolator为从血液中分离真菌提供了一种更快速、更灵敏的方法。

相似文献

5
Fungal blood cultures.真菌血培养
Eur J Clin Microbiol Infect Dis. 1989 Sep;8(9):825-31. doi: 10.1007/BF02185855.

引用本文的文献

3
Update on detection of bacteremia and fungemia.菌血症和真菌血症检测的最新进展。
Clin Microbiol Rev. 1997 Jul;10(3):444-65. doi: 10.1128/CMR.10.3.444.
7
Clinical implications of positive blood cultures.血培养阳性的临床意义。
Clin Microbiol Rev. 1989 Oct;2(4):329-53. doi: 10.1128/CMR.2.4.329.
8
Fungal blood cultures.真菌血培养
Eur J Clin Microbiol Infect Dis. 1989 Sep;8(9):825-31. doi: 10.1007/BF02185855.
9
Laboratory diagnosis of invasive candidiasis.侵袭性念珠菌病的实验室诊断
Clin Microbiol Rev. 1990 Jan;3(1):32-45. doi: 10.1128/CMR.3.1.32.

本文引用的文献

6
Detection of fungi in blood cultures.血培养中真菌的检测
J Clin Microbiol. 1975 Mar;1(3):309-10. doi: 10.1128/jcm.1.3.309-310.1975.
8
Recovery of yeast from vented blood culture bottles.从通气血培养瓶中回收酵母菌。
J Clin Microbiol. 1975 Jul;2(1):18-20. doi: 10.1128/jcm.2.1.18-20.1975.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验