Brain magnetic resonance imaging (MRI) examinations using high-resolution 3D post-contrast sequences offer increased sensitivity for the detection of metastases in the central nervous system but are usually long exams. We evaluated whether the diagnostic performance of a highly accelerated Wave-controlled aliasing in parallel imaging (Wave-CAIPI) post-contrast 3D T1 SPACE sequence was non-inferior to the standard high-resolution 3D T1 SPACE sequence for the evaluation of brain metastases. Thirty-three patients undergoing evaluation for brain metastases were prospectively evaluated with a standard post-contrast 3D T1 SPACE sequence and an optimized Wave-CAIPI 3D T1 SPACE sequence, which was three times faster than the standard sequence. Two blinded neuroradiologists performed a head-to-head comparison to evaluate the visualization of pathology, perception of artifacts, and the overall diagnostic quality. Wave-CAIPI post-contrast T1 SPACE was tested for non-inferiority relative to standard T1 SPACE using a 15% non-inferiority margin. Wave-CAIPI post-contrast T1 SPACE was non-inferior to the standard T1 SPACE for visualization of enhancing lesions ( < 0.01) and offered equivalent diagnostic quality performance and only marginally higher background noise compared to the standard sequence. Our findings suggest that Wave-CAIPI post-contrast T1 SPACE provides equivalent visualization of pathology and overall diagnostic quality with three times reduced scan time compared to the standard 3D T1 SPACE.
使用高分辨率三维对比后序列的脑磁共振成像(MRI)检查对中枢神经系统转移瘤的检测具有更高的灵敏度,但通常检查时间较长。我们评估了用于评估脑转移瘤的高度加速的并行成像中的波控混叠(Wave-CAIPI)对比后三维T1加权稳态采集快速成像(SPACE)序列的诊断性能是否不劣于标准高分辨率三维T1加权SPACE序列。对33例接受脑转移瘤评估的患者分别采用标准对比后三维T1加权SPACE序列和优化后的Wave-CAIPI三维T1加权SPACE序列进行前瞻性评估,后者比标准序列快三倍。两名盲法神经放射科医生进行了直接比较,以评估病变的可视化、伪影的感知以及总体诊断质量。使用15%的非劣效性边界测试Wave-CAIPI对比后T1加权SPACE相对于标准T1加权SPACE的非劣效性。Wave-CAIPI对比后T1加权SPACE在增强病变的可视化方面不劣于标准T1加权SPACE(<0.01),并提供了同等的诊断质量性能,与标准序列相比背景噪声仅略高。我们的研究结果表明,与标准三维T1加权SPACE相比,Wave-CAIPI对比后T1加权SPACE能提供同等的病变可视化和总体诊断质量,扫描时间减少了两倍。