Suppr超能文献

对医用口罩细菌过滤效率标准评估方法的新见解。

New insights into the standard method of assessing bacterial filtration efficiency of medical face masks.

机构信息

Mines Saint-Etienne, Univ Lyon, Univ Jean Monnet, INSERM, U 1059 Sainbiose, Centre CIS, 42023, Saint-Etienne, France.

École Nationale Supérieure Des Mines Saint Étienne, INSERM, U 1059 Sainbiose Centre CIS, 42023, Saint-Etienne, France.

出版信息

Sci Rep. 2021 Mar 15;11(1):5887. doi: 10.1038/s41598-021-85327-x.

Abstract

Based on the current knowledge of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) transmission, wearing a mask has been recommended during the COVID-19 pandemic. Bacterial filtration efficiency (BFE) measurements enable designing and regulating medical masks to prevent bioaerosol dissemination; however, despite the simplicity of these measurements, several scientific questions remain unanswered regarding BFE tests. Here, we investigated (1) the impact of substituting 100-mm Petri dishes with 90-mm disposable Petri dishes, (2) the impact of colony-counting methods on the bioaerosol aerodynamic size, and (3) the impact of colony-counting methods on the total viable particle counts. We demonstrated that disposable 90-mm Petri dishes can be used to replace the 100-mm dishes. We also showed that an automatic high-resolution colony counter can be used to directly count viable particles on collection substrates and to measure the bioaerosol size parameters. Our results enable possible modernization of the outdated testing methods recommended in the US and European standards for BFE measurements. Specifically, use of a modernized colony counter should be clearly regulated and permitted to avoid the counting of positive holes. The median aerodynamic diameter appears to be the most relevant parameter for characterizing bioaerosol size.

摘要

基于目前对严重急性呼吸综合征冠状病毒 2(SARS-CoV-2)传播的认识,在 COVID-19 大流行期间建议佩戴口罩。细菌过滤效率(BFE)测量可用于设计和规范医用口罩,以防止生物气溶胶传播;然而,尽管这些测量方法很简单,但关于 BFE 测试仍有几个科学问题尚未得到解答。在这里,我们研究了(1)用 90mm 一次性培养皿代替 100mm 培养皿对 BFE 测试的影响,(2)集落计数方法对生物气溶胶空气动力学粒径的影响,以及(3)集落计数方法对总活菌粒子计数的影响。我们证明了可以使用一次性 90mm 培养皿代替 100mm 培养皿。我们还表明,可以使用自动高分辨率集落计数器直接对收集基质上的活菌进行计数,并测量生物气溶胶的粒径参数。我们的结果使美国和欧洲标准中推荐的 BFE 测量的过时测试方法有可能实现现代化。具体来说,应明确规定和允许使用现代化的集落计数器,以避免对阳性孔进行计数。中值空气动力学直径似乎是表征生物气溶胶大小的最相关参数。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/0676/7960701/8a7db4165244/41598_2021_85327_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验