用于直接测量美式橄榄球中头部加速度的低功耗仪器化口罩的研制。

Development of a Low-Power Instrumented Mouthpiece for Directly Measuring Head Acceleration in American Football.

机构信息

Biomechanics Consulting and Research, LLC, 1627 Quail Run Drive, Charlottesville, VA, 22911, USA.

Center for Injury Research and Prevention, Children's Hospital of Philadelphia, Philadelphia, PA, 19146, USA.

出版信息

Ann Biomed Eng. 2021 Oct;49(10):2760-2776. doi: 10.1007/s10439-021-02826-8. Epub 2021 Jul 14.

Abstract

Instrumented mouthpieces (IM) offer a means of measuring head impacts that occur in sport. Direct measurement of angular head kinematics is preferential for accuracy; however, existing IMs measure angular velocity and differentiate the measurement to calculate angular acceleration, which can limit bandwidth and consume more power. This study presents the development and validation of an IM that uses new, low-power accelerometers for direct measurement of linear and angular acceleration over a broad range of head impact conditions in American football. IM sensor accuracy for measuring six-degree-of-freedom head kinematics was assessed using two helmeted headforms instrumented with a custom-fit IM and reference sensor instrumentation. Head impacts were performed at 10 locations and 6 speeds representative of the on-field conditions associated with injurious and non-injurious impacts in American football. Sensor measurements from the IM were highly correlated with those from the reference instrumentation located at the maxilla and skull center of gravity. Based on pooled data across headform and impact location, R ≥ 0.94, mean absolute error (AE) ≤ 7%, and mean relative impact angle ≤ 11° for peak linear and angular acceleration and angular velocity while R ≥ 0.90 and mean AE ≤ 7% for kinematic-based injury metrics used in helmet tests.

摘要

仪器化口部(IM)提供了一种测量运动中头部撞击的方法。为了提高准确性,最好直接测量头部的角运动;然而,现有的 IM 测量角速度,并通过微分测量来计算角加速度,这可能会限制带宽并消耗更多的功率。本研究提出了一种 IM 的开发和验证,该 IM 使用新的低功耗加速度计,可在美式橄榄球中广泛的头部撞击条件下直接测量线性和角加速度。使用定制的 IM 和参考传感器仪器化的两个头盔头模型评估了 IM 传感器测量六自由度头部运动学的准确性。在 10 个位置和 6 个速度下进行了头部撞击,这些位置和速度代表了与美式橄榄球中受伤和非受伤撞击相关的场上条件。IM 传感器的测量结果与位于上颌骨和颅骨重心的参考仪器的测量结果高度相关。基于对头模型和撞击位置的汇总数据,峰值线性和角加速度以及角速度的 R≥0.94,平均绝对误差(AE)≤7%,平均相对撞击角≤11°,而在头盔测试中使用的基于运动学的损伤指标的 R≥0.90,平均 AE≤7%。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验