氟离子导入对人牙本质自酸蚀黏结剂封闭能力的体外影响。

The effect of fluoride iontophoresis on seal ability of self-etch adhesive in human dentin in vitro.

机构信息

Department of Oral Biology, Faculty of Dentistry, Mahidol University, Yothi Road, Bangkok, 10400, Thailand.

Mahidol International Dental School, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.

出版信息

BMC Oral Health. 2022 Apr 2;22(1):109. doi: 10.1186/s12903-022-02146-w.

Abstract

BACKGROUND

Fluoride iontophoresis (FI) is a non-invasive method for the transfer of fluoride ions under electrical pressure into dental hard tissue. This study aimed to determine the effect of FI on the seal ability of self-etch adhesive in human dentin using dentin permeability test and scanning electron microscopy (SEM).

METHODS

The experiments were divided into 2 series: series 1 was performed on 28 extracted intact third molars and series 2 was performed on 28 extracted carious third molars (ICDAS 4 and 5). In each series, 20 teeth were used for dentin permeability test and 8 teeth were used for SEM study. For dentin permeability test, the specimens were divided into dentin without FI (control) and dentin with FI (experimental) subgroups. Hydraulic conductance (HD) of dentin was measured before and after adhesive treatment, and calculated for the percentage decrease of HD in each subgroup. Two-way ANOVA and Tukey test were used for statistical analysis. SEM study was used to assess the seal ability of self-etch adhesive and penetration of fluoride ions into dentinal tubules.

RESULTS

HD after self-etch adhesive treatment reduced by 57.75 ± 17.99% in intact dentin with FI, 46.60 ± 17.03% in intact dentin without FI, 45.00 ± 15.30% in caries affected dentin without FI, and 37.28 ± 14.72% in caries affected dentin with FI. There was no significant difference in percentage decrease of HD between dentin without FI and dentin with FI (P = 0.742); meanwhile, intact dentin with FI had significant greater percentage decrease than caries affected dentin with FI (P < 0.05). SEM findings showed FI produced more particle formation and deeper precipitation in intact dentin than those in caries affected dentin.

CONCLUSIONS

FI did not affect the seal ability of self-etch adhesive in human dentin when compared to without FI. However, FI could augment the seal ability of the self-etch adhesive in intact dentin better than that in caries affected dentin.

摘要

背景

氟离子电泳(FI)是一种在电场压力下将氟离子非侵入性地转移到牙体硬组织中的方法。本研究旨在通过牙本质通透性试验和扫描电子显微镜(SEM)来确定 FI 对自酸蚀粘结剂在人牙本质中密封能力的影响。

方法

实验分为两个系列:系列 1 在 28 个完整的第三磨牙上进行,系列 2 在 28 个龋坏的第三磨牙上进行(ICDAS 4 和 5)。在每个系列中,20 个牙齿用于牙本质通透性试验,8 个牙齿用于 SEM 研究。对于牙本质通透性试验,标本分为未经 FI(对照)和经 FI(实验)亚组的牙本质。在粘结剂处理前后测量牙本质的水力传导率(HD),并计算每个亚组 HD 的百分比降低。采用双因素方差分析和 Tukey 检验进行统计学分析。SEM 研究用于评估自酸蚀粘结剂的密封能力和氟离子渗透到牙本质小管中。

结果

FI 后自酸蚀粘结剂处理后,完整牙本质的 HD 分别降低了 57.75 ± 17.99%、FI 无完整牙本质的 HD 降低了 46.60 ± 17.03%、FI 无龋坏牙本质的 HD 降低了 45.00 ± 15.30%、FI 有龋坏牙本质的 HD 降低了 37.28 ± 14.72%。无 FI 的牙本质和有 FI 的牙本质之间 HD 降低的百分比无显著差异(P = 0.742);同时,FI 完整牙本质的 HD 降低百分比显著大于 FI 龋坏牙本质的 HD 降低百分比(P < 0.05)。SEM 结果显示,FI 在完整牙本质中产生的颗粒形成和沉淀深度比龋坏牙本质更深。

结论

与无 FI 相比,FI 对人牙本质中自酸蚀粘结剂的密封能力没有影响。然而,FI 可以增强自酸蚀粘结剂在完整牙本质中的密封能力,优于在龋坏牙本质中的密封能力。