Suppr超能文献

手动上睑提升对非接触眼压计测量眼压的影响。

Effect of manual upper eyelid elevation on intraocular pressure measurement by noncontact tonometer.

机构信息

Department of Ophthalmology, Istanbul Kartal Doctor Lütfi Kırdar City Hospital, Semsi Denizer Street, E-5, 34890, Kartal, Istanbul, Turkey.

出版信息

Int Ophthalmol. 2022 Sep;42(9):2915-2923. doi: 10.1007/s10792-022-02324-3. Epub 2022 May 13.

Abstract

PURPOSE

To evaluate whether manual upper eyelid elevation (MUEE) affects intraocular pressure (IOP) values obtained with a noncontact tonometer (NT).

METHODS

This cross-sectional study included 122 eyes of 122 non-glaucomatous adults. All patients underwent IOP measurement using both NT and Goldmann applanation tonometer (GAT). The order of measurements was NT without MUEE, NT with MUEE, and GAT. Both eyes of each patient were measured and one of the eyes was randomly selected for inclusion in the study. Central corneal thickness (CCT) and palpebral fissure height (PFH; distance between upper and lower eyelids) was recorded.

RESULTS

The patients' mean age was 43.91 ± 12.36 (20-61) years and 62.3% were women. Mean IOP values measured by NT without MUEE, NT with MUEE, and GAT were 15.98 ± 2.39, 15.84 ± 2.53, and 14.33 ± 2.3 mmHg, respectively. There was no statistically significant difference in mean IOP between NT without and with MUEE (p = 0.506). Mean IOP values obtained by NT with and without MUEE were significantly higher than those obtained by GAT (p < 0.001). The difference in IOP values measured by NT without and with MUEE was positively correlated with PFH (r = 0.214; p = 0.018). CCT and IOP values obtained by NT without MUEE and GAT were positively correlated (r = 0.300; p = 0.001 and r = 0.311; p = 0.001, respectively).

CONCLUSION

MUEE does not have a significant effect on IOP measurements by NT. The difference between IOP measured by NT without and with MUEE increases with greater PFH.

摘要

目的

评估手动上睑提升(MUEE)是否会影响非接触眼压计(NT)测量得到的眼压(IOP)值。

方法

本横断面研究纳入了 122 例非青光眼成年患者的 122 只眼。所有患者均接受 NT 和 Goldmann 压平眼压计(GAT)的 IOP 测量。测量顺序为:无 MUEE 的 NT、有 MUEE 的 NT 和 GAT。每位患者的双眼均进行了测量,并随机选择一只眼纳入研究。记录中央角膜厚度(CCT)和睑裂高度(PFH;上下眼睑之间的距离)。

结果

患者的平均年龄为 43.91±12.36 岁(20-61 岁),其中 62.3%为女性。无 MUEE 的 NT、有 MUEE 的 NT 和 GAT 测量的平均 IOP 值分别为 15.98±2.39mmHg、15.84±2.53mmHg 和 14.33±2.3mmHg。无 MUEE 的 NT 和有 MUEE 的 NT 之间的平均 IOP 差异无统计学意义(p=0.506)。有 MUEE 的 NT 测量的平均 IOP 值明显高于 GAT(p<0.001)。无 MUEE 和有 MUEE 的 NT 测量的 IOP 值差异与 PFH 呈正相关(r=0.214;p=0.018)。无 MUEE 的 NT 和 GAT 测量的 CCT 和 IOP 值呈正相关(r=0.300;p=0.001 和 r=0.311;p=0.001)。

结论

MUEE 对视神经检测的 IOP 测量值没有显著影响。无 MUEE 和有 MUEE 的 NT 测量的 IOP 值之间的差异随着 PFH 的增加而增大。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验