Sporer Markus, Reich Stefan, Kauffman John G, Ortmanns Maurits
IEEE Trans Biomed Circuits Syst. 2022 Jun;16(3):409-418. doi: 10.1109/TBCAS.2022.3177241. Epub 2022 Jul 12.
This article presents a direct digitizing neural recorder that uses a body-induced offset based DC servo loop to cancel electrode offset (EDO) on-chip. The bulk of the input pair is used to create an offset, counteracting the EDO. The architecture does not require AC coupling capacitors which enables the use of chopping without impedance boosting while maintaining a large input impedance of 238 M Ω over the whole 10 kHz bandwidth. Implemented in a 180 nm HV-CMOS process, the prototype occupies a silicon area of only 0.02 mm while consuming 12.8 μW and achieving 1.82 μV[Formula: see text] of input-referred noise in the local field potential (LFP) band and a NEF of 5.75.