Suppr超能文献

使用 Airstretcher 进行拖拽可能会减轻救援人员在将患者从楼梯上往下运送时的体力负担。

Use of the Airstretcher with dragging may reduce rescuers' physical burden when transporting patients down stairs.

机构信息

Department of Emergency Medical Sciences, Niigata University of Health and Welfare, Niigata, Japan.

Department of Prehospital Emergency Medical Sciences, Hiroshima International University, Hiroshima, Japan.

出版信息

PLoS One. 2022 Sep 14;17(9):e0274604. doi: 10.1371/journal.pone.0274604. eCollection 2022.

Abstract

Transporting patients down stairs by carrying is associated with a particularly high fall risk for patients and the occurrence of back pain among emergency medical technicians. The present study aimed to verify the effectiveness of the Airstretcher device, which was developed to reduce rescuers' physical burden when transporting patients by dragging along the floor and down stairs. Forty-one paramedical students used three devices to transport a 65-kg manikin down stairs from the 3rd to the 1st floor. To verify the physical burden while carrying the stretchers, ratings of perceived exertion were measured using the Borg CR10 scale immediately after the task. Mean Borg CR10 scores (standard deviation) were 3.6 (1.7), 4.1 (1.8), 5.6 (2.4), and 4.2 (1.8) for the Airstretcher with dragging, Airstretcher with lifting, backboard with lifting, and tarpaulin with lifting conditions, respectively (p < 0.01). Multiple comparisons revealed that the Airstretcher with dragging condition was associated with significantly lower Borg CR10 scores compared with the backboard with lifting condition (p < 0.01). When the analysis was divided by handling position, estimated Borg CR10 values (standard error) for head position were 4.4 (1.3), 2.9 (0.9), 3.2 (0.8), and 4.0 (1.1) for the Airstretcher with dragging, Airstretcher with lifting, backboard with lifting, and tarpaulin with lifting conditions, respectively, after adjusting for participant and duration time (F = 1.4, p < 0.25). The estimated Borg CR10 value (standard error) for toe position in the Airstretcher with dragging condition was 2.0 (0.8), and the scores for the side position were 4.9 (0.4), 6.1 (0.3), and 4.7 (0.4) for the Airstretcher with lifting, backboard with lifting, and tarpaulin with lifting conditions, respectively, after adjusting for participant and duration time (F = 3.6, p = 0.02). Transferring a patient down stairs inside a house by dragging using the Airstretcher may reduce the physical burden for rescuers.

摘要

用担架搬运患者下楼梯会使患者跌倒的风险特别高,同时也会使急救医疗技术员背痛。本研究旨在验证 Airstretcher 设备的有效性,该设备旨在减少救援人员在沿地板和下楼梯拖动患者时的体力负担。41 名辅助医疗专业学生使用三种设备将一个 65 公斤的人体模型从 3 楼运到 1 楼。为了验证搬运担架时的体力负担,使用 Borg CR10 量表在任务后立即测量感知用力程度的评分。Airstretcher 拖动、Airstretcher 提升、背板提升和篷布提升条件下的平均 Borg CR10 评分(标准差)分别为 3.6(1.7)、4.1(1.8)、5.6(2.4)和 4.2(1.8)(p<0.01)。多重比较显示,Airstretcher 拖动条件与背板提升条件相比,Borg CR10 评分显著降低(p<0.01)。当按处理位置进行分析时,头部位置的估计 Borg CR10 值(标准误差)分别为 Airstretcher 拖动、Airstretcher 提升、背板提升和篷布提升条件下的 4.4(1.3)、2.9(0.9)、3.2(0.8)和 4.0(1.1),调整参与者和持续时间后(F=1.4,p<0.25)。在 Airstretcher 拖动条件下,脚趾位置的估计 Borg CR10 值(标准误差)为 2.0(0.8),而在 Airstretcher 提升、背板提升和篷布提升条件下,侧身位置的评分分别为 4.9(0.4)、6.1(0.3)和 4.7(0.4),调整参与者和持续时间后(F=3.6,p=0.02)。在室内用 Airstretcher 拖动患者下楼梯可能会减轻救援人员的体力负担。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3822/9473625/6111595a5bf6/pone.0274604.g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验