OBJECTIVES

Due to the limited longevity of endovascular leads, children require thoughtful lifetime lead management strategies including conservation of access vessel patency. Consequently, there is an increasing interest in transvenous lead extraction (TLE) in children, however, data on TLE and the use of powered mechanical dissection sheaths is limited.

METHODS

We performed a retrospective cohort study analyzing all children <18 years that underwent TLE in our institution from 2015 to 2022. Procedural complexity, results and complications were defined as recommended by recent consensus statements.

RESULTS

Twenty-eight children [median age 12.8 (interquartile range 11.3-14.6) years] were included. Forty-one leads were extracted [median dwell time 85 (interquartile range 52-102) months]. Extractions of 31 leads (76%) in 22 patients (79%) were complex, requiring advanced extraction tools including powered bidirectional rotational dissection sheaths in 14 children. There were no major complications. Complete procedural success was achieved in 18 (64%) and clinical success in 27 patients (96%), respectively. Procedural success and complexity varied between lead types. The Medtronic SelectSecure™ lead was associated with increased odds of extraction by simple traction ( = 0.006) and complete procedural success ( < 0.001) while the Boston Scientific Fineline™ II lead family had increased odds of partial procedural failure ( = 0.017).

CONCLUSIONS

TLE with the use of mechanical powered rotational dissection sheaths is feasible and safe in pediatric patients. In light of rare complications and excellent overall clinical success, TLE should be considered an important cornerstone in lifetime lead management in children. Particular lead types might be more challenging and less successful to extract.

摘要

目的

由于血管内导线的使用寿命有限,儿童需要精心制定终身导线管理策略,包括保持入路血管通畅。因此,人们对儿童经静脉导线拔除术(TLE)的兴趣日益增加,然而,关于TLE和使用动力机械分离鞘的数据有限。

方法

我们进行了一项回顾性队列研究,分析了2015年至2022年在我们机构接受TLE的所有18岁以下儿童。程序复杂性、结果和并发症按照最近的共识声明进行定义。

结果

纳入了28名儿童[中位年龄12.8(四分位间距11.3 - 14.6)岁]。共拔除41根导线[中位留置时间85(四分位间距52 - 102)个月]。22名患者(79%)的31根导线(76%)拔除过程复杂,需要先进的拔除工具,其中14名儿童使用了动力双向旋转分离鞘。无重大并发症。分别有18例(64%)实现了完全手术成功,27例患者(96%)实现了临床成功。手术成功率和复杂性因导线类型而异。美敦力SelectSecure™导线通过简单牵引拔除的几率增加( = 0.006)且完全手术成功率更高( < 0.001),而波士顿科学Fineline™ II导线家族部分手术失败的几率增加( = 0.017)。

结论

在儿科患者中,使用动力机械旋转分离鞘进行TLE是可行且安全的。鉴于并发症罕见且总体临床成功率高,TLE应被视为儿童终身导线管理的重要基石。特定类型的导线拔除可能更具挑战性且成功率较低。