• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Continuous measurement of oxygen uptake. Evaluation of the Engström metabolic computer and clinical experiences.

作者信息

Behrendt W, Weiland C, Kalff J, Giani G

出版信息

Acta Anaesthesiol Scand. 1987 Jan;31(1):10-4. doi: 10.1111/j.1399-6576.1987.tb02511.x.

DOI:10.1111/j.1399-6576.1987.tb02511.x
PMID:3825470
Abstract

A new system for continuous measurement of oxygen uptake was tested. The tidal volumes delivered by the system, the accuracy of the oxygen sensor cell, measurement of the oxygen uptake at different inspired oxygen concentrations, and comparative tests of oxygen uptake using the Fick principle were studied. Judging from our results, even thorough maintenance could not entirely prevent leakages. Due to a construction error, there was a large increase in measured oxygen uptake if inspired oxygen concentration was increased. While carbon-dioxide output was constant, this led to respiratory quotients of less than 0.5. By modifying the system with a mixing chamber for the inspiratory gas, new tubing to the oxygen sensor cell and changes in the computer software, these errors have been corrected in the meantime. In comparative tests of oxygen uptake using the Fick principle (cardiac output and arteriovenous oxygen content difference), we found a mean difference between EMC and the Fick principle of about 6.6% (P less than or equal to 0.001, r = 0.91) with nearly identical standard deviations for both values. Our experience indicates that the EMC is suitable for continuous measurements of oxygen uptake. Additional technical improvements seem to be possible.

摘要

相似文献

1
Continuous measurement of oxygen uptake. Evaluation of the Engström metabolic computer and clinical experiences.
Acta Anaesthesiol Scand. 1987 Jan;31(1):10-4. doi: 10.1111/j.1399-6576.1987.tb02511.x.
2
[Continuous measurement of oxygen uptake using the Engström Metabolic Computer].[使用恩斯特龙代谢计算机连续测量摄氧量]
Infusionsther Klin Ernahr. 1985 Jun;12(3):153-60.
3
Continuous measurement of cardiac output by the Fick principle: clinical validation in intensive care.通过菲克原理连续测量心输出量:重症监护中的临床验证
Crit Care Med. 1992 Mar;20(3):360-5. doi: 10.1097/00003246-199203000-00012.
4
[Initial clinical experiences with the S & W Kaloximet, a device for measuring oxygen consumption in anesthesia and intensive medicine].[使用S&W Kaloximet的初步临床经验,一种用于麻醉和重症医学中测量耗氧量的设备]
Anaesthesist. 1989 Mar;38(3):147-51.
5
Evaluation of an apparatus for continuous monitoring of gas exchange in mechanically ventilated patients.
Int J Clin Monit Comput. 1985;1(4):211-20. doi: 10.1007/BF01720185.
6
[Continuous Fick cardiac output measurement during inhalation anesthesia].[吸入麻醉期间连续测量心输出量的Fick法]
Hokkaido Igaku Zasshi. 1992 Mar;67(2):161-73.
7
A system for the continuous measurement of oxygen uptake and carbon dioxide output in artificially ventilated patients.一种用于连续测量人工通气患者氧气摄取量和二氧化碳排出量的系统。
Br J Anaesth. 1983 Aug;55(8):791-800. doi: 10.1093/bja/55.8.791.
8
Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.心脏手术后新生儿和婴儿氧气消耗的实时气体交换测量
Crit Care Med. 1993 Sep;21(9):1369-75. doi: 10.1097/00003246-199309000-00022.
9
A system to simulate gas exchange in humans to control quality of metabolic measurements.一种模拟人体气体交换以控制代谢测量质量的系统。
Eur J Appl Physiol Occup Physiol. 1998 Nov;78(6):549-54. doi: 10.1007/s004210050459.
10
Oxygen Fick and modified carbon dioxide Fick cardiac outputs.氧耗量菲克法和改良二氧化碳菲克法心输出量。
Crit Care Med. 1994 Jan;22(1):86-95. doi: 10.1097/00003246-199401000-00018.

引用本文的文献

1
Continuous measurement of oxygen consumption using the reversed fick method.使用反向菲克法连续测量耗氧量。
J Anesth. 1997 Mar;11(1):27-31. doi: 10.1007/BF02480001.
2
Immediate metabolic effects of different nutritional regimens in critically ill medical patients.
Intensive Care Med. 1995 Jul;21(7):561-6. doi: 10.1007/BF01700160.
3
Oxygen consumption after cardiac surgery--a comparison between calculation by Fick's principle and measurement by indirect calorimetry.心脏手术后的氧消耗——基于菲克原理的计算法与间接量热法测量结果的比较
Intensive Care Med. 1992;18(4):206-9. doi: 10.1007/BF01709833.