Suppr超能文献

一种用于诊断系统性念珠菌病的反向被动乳胶凝集试验。

A reverse passive latex agglutination test for the diagnosis of systemic candidosis.

作者信息

Burnie J

出版信息

J Immunol Methods. 1985 Oct 10;82(2):267-80. doi: 10.1016/0022-1759(85)90359-x.

Abstract

A new reverse passive latex agglutination test for the detection of serum antigen in systemic Candida albicans infection is reported. 1700 sera were examined from 91 patients who had either proven or suspected systemic candidosis, 183 patients who were colonized and 636 patients with no evidence of candidal infection. Thirty of the systemically infected patients had lymphoproliferative disorders and the rest a variety of surgical or medical diseases with no underlying neutropenia. The latex particles were sensitised with an antiserum raised in rabbits against a pressate of Candida albicans. The degree of antigenaemia was proportional to the likelihood of invasive disease such that a diagnostic cut-off point of 1 in 8 produced a test for systemic candidosis with a sensitivity of 90% and specificity of 80.4% in patients with lymphoproliferative disorders. In the remaining medical and surgical patients a diagnostic cut-off point of 1 in 10 produced a test with a sensitivity of 96.7% and specificity of 98.8%. The patients with lymphoproliferative disorders tended to produce lower serum antigen levels. The sera were also assayed for antibody using latex particles sensitised with pressate.

摘要

本文报道了一种用于检测系统性白色念珠菌感染血清抗原的新型反向被动乳胶凝集试验。对91例已确诊或疑似系统性念珠菌病的患者、183例念珠菌定植患者以及636例无念珠菌感染证据的患者的1700份血清进行了检测。30例系统性感染患者患有淋巴增殖性疾病,其余患者患有各种外科或内科疾病,但无潜在的中性粒细胞减少症。用兔抗白色念珠菌提取物抗血清致敏乳胶颗粒。抗原血症程度与侵袭性疾病的可能性成正比,因此在淋巴增殖性疾病患者中,诊断截断值为1/8时,系统性念珠菌病检测的敏感性为90%,特异性为80.4%。在其余的内科和外科患者中,诊断截断值为1/10时,检测的敏感性为96.7%,特异性为98.8%。淋巴增殖性疾病患者的血清抗原水平往往较低。还用提取物致敏的乳胶颗粒检测了血清中的抗体。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验