A simplified method has been developed for agar dilution antimicrobial susceptibility testing of anaerobic bacteria, designed to economize on time and money when only a few isolates need to be tested. The procedure is based on the principle of using filter paper disks as carriers of the antibiotic and 35- by 10-mm petri dishes which, when inoculated with the Steers replicator, can test up to four organisms per plate. The procedure was run in parallel with conventional agar dilution techniques and showed 95% agreement to within one dilution for all minimal inhibitory concentrations recorded on fresh anaerobic isolates from clinical specimens. The technique was further simplified by using commercially available antibiotic-containing disks, thereby alleviating the tedious and time-consuming procedure of preparing the disks. The data indicated that 48- to 72-h diffusion periods were sufficient to achieve a uniform concentration of the antibiotic in the petri plate and that the antibiotics were stable at room temperature for that period of time. In terms of applicability and relevance to the needs of the clinical microbiology laboratory, the modified agar dilution method for rapid antimicrobial susceptibility testing of individual anaerobic isolates was found to be superior to the broth dilution method since it was easier to read and required considerably less set up time.

摘要

已开发出一种用于厌氧菌琼脂稀释抗菌药敏试验的简化方法,旨在仅需检测少量分离株时节省时间和金钱。该程序基于使用滤纸圆盘作为抗生素载体的原理,以及35×10毫米的培养皿,当用Steers复制器接种时,每个平板可检测多达四种微生物。该程序与传统琼脂稀释技术并行运行,对于从临床标本中分离出的新鲜厌氧菌记录的所有最低抑菌浓度,显示出95%的一致性在一个稀释度范围内。通过使用市售含抗生素圆盘,该技术进一步简化,从而省去了制备圆盘这一繁琐且耗时的程序。数据表明,48至72小时的扩散期足以在培养皿中实现抗生素浓度均匀,且在此期间抗生素在室温下稳定。就临床微生物实验室需求的适用性和相关性而言,发现用于单个厌氧菌分离株快速抗菌药敏试验的改良琼脂稀释法优于肉汤稀释法,因为它更易于读取,且所需的设置时间少得多。

相似文献

5
Antimicrobial susceptibility testing of anaerobic bacteria.厌氧菌的药敏试验
Rev Infect Dis. 1984 Mar-Apr;6 Suppl 1:S242-8. doi: 10.1093/clinids/6.supplement_1.s242.

本文引用的文献

8
A new method for antibiotic sensitivity testing.
Lancet. 1971 Oct 2;2(7727):745-6. doi: 10.1016/s0140-6736(71)92110-6.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验