Suppr超能文献

使用超声设备进行吞咽相关肌肉评估的评分者内和评分者间信度

Intra- and inter-rater reliability of swallowing-related muscle assessments using ultrasound devices.

作者信息

Ishino Shota, Nagasaka Motoomi, Kawamura Koki, Masuda Yuto, Kamiya Masaki, Iwase Taku, Maeda Keisuke, Kagaya Hitoshi

机构信息

Department of Rehabilitation, National Center for Geriatrics and Gerontology, 7-430, Morioka, Obu, Aichi, 474-8511, Japan.

Department of Palliative and Supportive Medicine, Graduate School of Medicine, Aichi Medical University, 1-1 Yazakokarimata, Nagakute, Aichi, 480-1195, Japan.

出版信息

J Ultrasound. 2025 Aug 25. doi: 10.1007/s40477-025-01069-w.

Abstract

PURPOSE

To evaluate the inter- and intra-assessor reliability of ultrasonographic assessment of swallowing-related muscle indices in healthy young adults.

METHODS

Three examiners conducted ultrasonographic evaluations on healthy young adults (n = 34, age: ≥ 20 years) examining the thickness and area of the geniohyoid muscle, anterior belly of the digastric muscle, tongue, and the mylohyoid, masseter, and depressor anguli oris muscles. To assess inter-rater reliability, each examiner evaluated each assessment item for one subject three times on the same day. Intra-rater reliability was assessed by rater No. 3 re-evaluating the participants 4-7 days after the initial measurement, using the retest method. Image analysis was conducted by a single examiner utilizing an ultrasonography measurement tool. Statistical analysis was performed using intraclass correlation coefficients (ICCs) for intra- and inter-rater reliability.

RESULTS

The study included 34 participants (male: 17, female: 17; age: 25 ± 2 years, body mass index: 20.3 ± 1.7 kg/m). For intra-rater reliability for thickness of the geniohyoid muscle, ICC = 0.94 [95% CI (0.89, 0.97)], and ICC = 0.90 [95% CI (0.81, 0.93)] for the area of the anterior belly of the digastric muscle. For inter-rater reliability, ICC = 0.93 [95% CI (0.88, 0.96)] and 0.86 [95% CI (0.77, 0.92)] for the thickness of the geniohyoid muscle, and area of the anterior belly of the digastric muscle, respectively.

CONCLUSIONS

The inter- and intra-assessor reliability of ultrasound assessments of swallowing-related indices in young healthy subjects was good, exhibiting particularly high accuracy for the geniohyoid muscle and the anterior belly of the digastric muscle.

摘要

目的

评估超声评估健康年轻成年人吞咽相关肌肉指标时评估者间和评估者内的可靠性。

方法

三名检查者对健康年轻成年人(n = 34,年龄:≥20岁)进行超声评估,检查颏舌骨肌、二腹肌前腹、舌以及下颌舌骨肌、咬肌和降口角肌的厚度和面积。为评估评估者间可靠性,每位检查者在同一天对一名受试者的每个评估项目进行三次评估。评估者内可靠性通过检查者3在初次测量后4 - 7天使用重测法对参与者进行重新评估来评估。图像分析由一名检查者使用超声测量工具进行。使用组内相关系数(ICC)进行评估者内和评估者间可靠性的统计分析。

结果

该研究纳入34名参与者(男性:17名,女性:17名;年龄:25±2岁,体重指数:20.3±1.7kg/m)。颏舌骨肌厚度的评估者内可靠性,ICC = 0.94 [95%CI(0.89,0.97)],二腹肌前腹面积的ICC = 0.90 [95%CI(0.81,0.93)]。评估者间可靠性方面,颏舌骨肌厚度的ICC = 0.93 [95%CI(0.88,0.96)],二腹肌前腹面积的ICC = 0.86 [95%CI(0.77,0.92)]。

结论

健康年轻受试者吞咽相关指标超声评估的评估者间和评估者内可靠性良好,对颏舌骨肌和二腹肌前腹表现出特别高的准确性。