Chu C C
Ann Surg. 1982 Jan;195(1):55-9. doi: 10.1097/00000658-198201001-00009.
The differences in hydrolytic degradation of two size 2-0 synthetic absorbable sutures, Polyglycolic acid (Dexon) and Poly(glycolide-lactide) (Vicryl), in the buffer media of three different pH levels ranging from 5.25 to 10.09, were compared in terms of the percentage retention of tensile strength. It was found that Vicryl sutures, in general, exhibited better retention of tensile strength than Dexon sutures within the studied pH range and extent of hydrolysis. When comparing Vicryl with Dexon sutures, the former was only slightly better than Dexon sutures, in the case of an acid environment. The former, however, retained better strength than the latter in a physiological pH (7.44) and under high-alkaline conditions (10.09). Among the three pH levels tested, Vicryl sutures retained the highest tensile strength in a physiological pH and showed a faster loss of tensile strength in both acidic and high-alkaline conditions. Dexon sutures, however, exhibited better retention of tensile strength in the acidic medium than in an alkaline medium. This pH dependent hydrolysis of Dexon and Vicryl sutures should command surgeons' attention in their selection of synthetic absorbable suture materials for particular needs.
比较了两种2-0号合成可吸收缝线,聚乙醇酸(Dexon)和聚(乙交酯-丙交酯)(Vicryl),在pH值范围从5.25至10.09的三种不同缓冲介质中水解降解时拉伸强度的保留百分比差异。结果发现,在研究的pH值范围和水解程度内,一般来说,Vicryl缝线比Dexon缝线表现出更好的拉伸强度保留率。将Vicryl缝线与Dexon缝线比较时,在酸性环境下,前者仅比Dexon缝线略好。然而,在生理pH值(7.44)和高碱性条件(10.09)下,前者比后者保留了更好的强度。在测试的三个pH值水平中,Vicryl缝线在生理pH值下保留了最高的拉伸强度,并且在酸性和高碱性条件下均显示出更快的拉伸强度损失。然而,Dexon缝线在酸性介质中比在碱性介质中表现出更好的拉伸强度保留率。Dexon和Vicryl缝线这种pH依赖性水解在外科医生为特定需求选择合成可吸收缝合材料时应引起他们的注意。