Ten cylindrical implants, made of polycarbonate and covered with a 120-250-nm-thick layer of pure titanium, were implanted into each tibial metaphysis of five rabbits. Observation time was 12 weeks. The implants were surrounded by mature, living bone. No soft tissue intervened between bone and implant at any point. With TEM microscopy the titanium was shown to be bordered by a 20-nm-thick layer of proteoglycans, showing the characteristics of ground substance, and separating the collagen from the implant surface. Cells at the interface were likewise separated from the titanium by such a layer. Hydroxyapatite crystals were observed within the ground substance layer, occasionally seemingly in direct contact with the titanium. Normal mineralization was present 100-500 nm from the implant surface. While this study aims at defining interface anatomy, it also shows that macroscopically smooth-surfaced titanium can readily heal into bone without a soft tissue envelope. This could be of help for materials' choice and design of permanently fixed implants.

摘要

将十个由聚碳酸酯制成并覆盖有一层120 - 250纳米厚纯钛的圆柱形植入物,植入五只兔子的每只胫骨近端干骺端。观察时间为12周。植入物被成熟的活骨包围。在骨与植入物之间的任何部位都没有软组织介入。通过透射电子显微镜观察发现,钛被一层20纳米厚的蛋白聚糖层所界定,该层呈现出细胞外基质的特征,并将胶原蛋白与植入物表面分隔开。界面处的细胞同样被这样一层物质与钛分隔开。在细胞外基质层内观察到了羟基磷灰石晶体,偶尔似乎与钛直接接触。在距植入物表面100 - 500纳米处存在正常矿化现象。虽然本研究旨在明确界面解剖结构,但它也表明宏观上表面光滑的钛能够很容易地在没有软组织包膜的情况下与骨愈合。这对于材料选择和永久固定植入物的设计可能会有帮助。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验