含BACTEC树脂血培养瓶的体外评估

In vitro evaluation of the BACTEC resin-containing blood culture bottle.

作者信息

Smith S M, Eng R H

出版信息

J Clin Microbiol. 1983 Jun;17(6):1120-6. doi: 10.1128/jcm.17.6.1120-1126.1983.

Abstract

The BACTEC resin-containing blood culture bottle (16B; Johnston Laboratories) was designed to bind antibiotics and to support bacterial growth. However, only modest increases in the recovery rates of pathogens have been found in clinical studies. This in vitro study evaluated the ability of the 16B to recover organisms from human serum containing clinically achievable concentrations of antibiotics. Escherichia coli, Enterobacter cloacae, Klebsiella pneumoniae, Pseudomonas aeruginosa, Haemophilus influenzae, Staphylococcus aureus, Streptococcus faecalis, and a viridans streptococcus were added to serum containing antibiotic(s), and at various time intervals of antibiotic exposure, portions were removed and inoculated into both the 16B and the 6B (conventional aerobic) bottles. The studies of the kinetics of killing of the bacterial strains by the various antibiotics showed a good correlation between those combinations of bacteria-antibiotic(s) which produced slow killing and the combinations of bacteria-antibiotic(s) which were recovered preferentially in the 16B bottles. Low recovery rates were noted when the antibiotics killed the organisms rapidly. The indications for use of the resin-containing blood culture bottle should be limited to those situations in which the patient is receiving antibiotics and the bacteremia is suspected to involve a pathogen which is killed slowly by the administered drug(s) or when the bacteremia is continuous. The failure of the BACTEC 16B blood culture bottle to recover organisms may in part reflect the bactericidal activity of the antibiotics administered.

摘要

BACTEC含树脂血培养瓶(16B;约翰斯顿实验室)旨在结合抗生素并支持细菌生长。然而,临床研究发现病原体回收率仅适度提高。这项体外研究评估了16B从含有临床可达到浓度抗生素的人血清中回收微生物的能力。将大肠杆菌、阴沟肠杆菌、肺炎克雷伯菌、铜绿假单胞菌、流感嗜血杆菌、金黄色葡萄球菌、粪肠球菌和一株草绿色链球菌添加到含有抗生素的血清中,在抗生素暴露的不同时间间隔,取出部分血清并接种到16B瓶和6B(传统需氧)瓶中。对各种抗生素杀灭细菌菌株动力学的研究表明,产生缓慢杀灭作用的细菌 - 抗生素组合与在16B瓶中优先回收的细菌 - 抗生素组合之间存在良好的相关性。当抗生素迅速杀灭微生物时,回收率较低。含树脂血培养瓶的使用指征应限于患者正在接受抗生素治疗且怀疑菌血症涉及被所用药物缓慢杀灭的病原体的情况,或菌血症持续的情况。BACTEC 16B血培养瓶未能回收微生物可能部分反映了所用抗生素的杀菌活性。

相似文献

1
In vitro evaluation of the BACTEC resin-containing blood culture bottle.
J Clin Microbiol. 1983 Jun;17(6):1120-6. doi: 10.1128/jcm.17.6.1120-1126.1983.
3
Evaluation of the BACTEC antimicrobial removal system for detection of bacteremia.
J Clin Microbiol. 1983 Sep;18(3):449-51. doi: 10.1128/jcm.18.3.449-451.1983.
4
Detection of bacteremia with the BACTEC 16B resin blood culture medium.
Am J Clin Pathol. 1984 May;81(5):643-6. doi: 10.1093/ajcp/81.5.643.
9
Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.
J Clin Microbiol. 1992 Feb;30(2):323-9. doi: 10.1128/jcm.30.2.323-329.1992.
10
Simulated Pediatric Blood Cultures to Assess the Inactivation of Clinically Relevant Antimicrobial Drug Concentrations in Resin-Containing Bottles.
Front Cell Infect Microbiol. 2021 Mar 19;11:649769. doi: 10.3389/fcimb.2021.649769. eCollection 2021.

引用本文的文献

1
Impact of low blood culture usage on rates of antimicrobial resistance.
J Infect. 2021 Mar;82(3):355-362. doi: 10.1016/j.jinf.2020.10.040. Epub 2020 Dec 2.
3
PCR and blood culture for detection of Escherichia coli bacteremia in rats.
J Clin Microbiol. 1999 Aug;37(8):2479-82. doi: 10.1128/JCM.37.8.2479-2482.1999.
4
Elimination of quinolone antibiotic carryover through use of antibiotic-removal beads.
Antimicrob Agents Chemother. 1993 Jun;37(6):1377-9. doi: 10.1128/AAC.37.6.1377.
5
Evaluation of new blood culture processing systems.
J Clin Microbiol. 1984 Sep;20(3):351-6. doi: 10.1128/jcm.20.3.351-356.1984.
6
Occurrence of bacteremia in hematologic patients.
Eur J Epidemiol. 1992 Sep;8(5):687-92. doi: 10.1007/BF00145385.

本文引用的文献

1
Evaluation of the Antibiotic Removal Device.
J Clin Microbiol. 1982 Feb;15(2):278-81. doi: 10.1128/jcm.15.2.278-281.1982.
2
The antimicrobial removal device. A microbiological and clinical evaluation.
Am J Clin Pathol. 1982 Aug;78(2):173-7. doi: 10.1093/ajcp/78.2.173.
3
In vitro antibiotic removal and bacterial recovery from blood with an antibiotic removal device.
J Clin Microbiol. 1981 Mar;13(3):503-7. doi: 10.1128/jcm.13.3.503-507.1981.
4
Enhanced detection of bacteremia with a new BACTEC resin blood culture medium.
J Clin Microbiol. 1983 Jan;17(1):48-51. doi: 10.1128/jcm.17.1.48-51.1983.
5
Rapid isolation of bacteria from septicemic patients by use of an antimicrobial agent removal device.
J Clin Microbiol. 1980 May;11(5):462-4. doi: 10.1128/jcm.11.5.462-464.1980.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验