Knapp C C, Ludwig M D, Washington J A
Department of Clinical Pathology, Cleveland Clinic Foundation, Ohio 44195.
J Clin Microbiol. 1994 Feb;32(2):433-6. doi: 10.1128/jcm.32.2.433-436.1994.
This study was conducted in order to compare the accuracy of detection of oxacillin-resistant staphylococci, defined by microdilution MICs, population analyses, and mec gene hybridization, with the Vitek GPS-SA Susceptibility Card with that of the standard inoculum (10(7) CFU) and high-inoculum (10(9) CFU) disk diffusion tests. By the standard inoculum disk diffusion test, 10 of 67 (15%) isolates of oxacillin-resistant Staphylococcus aureus and 3 of 47 (6%) isolates of Staphylococcus epidermidis were falsely susceptible after 24 h of incubation at 35 degrees C. By the high-inoculum disk diffusion test (10(9) CFU), 4 of the 10 isolates of S. aureus remained falsely susceptible, whereas none of the isolates of S. epidermidis was falsely susceptible. Of the 10 isolates of S. aureus falsely susceptible by the standard disk test, only one remained falsely susceptible after an additional 24 h of incubation at 22 degrees C. All four isolates of S. aureus that were falsely susceptible by the high-inoculum disk diffusion test after 24 h of incubation at 35 degrees C became resistant after an additional 24 h of incubation at 22 degrees C. Thus, extended incubation of both the standard and high-inoculum disk diffusion tests increased their accuracy in detecting oxacillin resistance. All isolates of oxacillin-resistant staphylococci were accurately detected with the Vitek software upgrades (6.1 and 7.1) of the GPS-SA card.
本研究旨在比较通过微量稀释法测定的最低抑菌浓度(MIC)、群体分析法和mec基因杂交法所定义的耐苯唑西林葡萄球菌的检测准确性,以及Vitek GPS-SA药敏卡与标准接种量(10⁷CFU)和高接种量(10⁹CFU)纸片扩散试验的准确性。通过标准接种量纸片扩散试验,在35℃孵育24小时后,67株耐苯唑西林金黄色葡萄球菌中有10株(15%)和47株表皮葡萄球菌中有3株(6%)被误判为敏感。通过高接种量纸片扩散试验(10⁹CFU),10株金黄色葡萄球菌中有4株仍被误判为敏感,而表皮葡萄球菌中无一株被误判为敏感。在标准纸片试验中被误判为敏感的10株金黄色葡萄球菌中,只有1株在22℃额外孵育24小时后仍被误判为敏感。在35℃孵育24小时后通过高接种量纸片扩散试验被误判为敏感的所有4株金黄色葡萄球菌,在22℃额外孵育24小时后均变为耐药。因此,标准和高接种量纸片扩散试验的延长孵育时间提高了它们检测苯唑西林耐药性的准确性。使用GPS-SA卡的Vitek软件升级版(6.1和7.1)能准确检测出所有耐苯唑西林葡萄球菌菌株。