The laser flare cell meter (LFCM) was used to evaluate alterations of the blood-aqueous barrier in eyes with retinal vein occlusion (RVO). In 42 eyes of 42 patients with RVO (30 branch vein occlusions, 12 central vein occlusions) aqueous flare and aqueous cells were determined and retinal fluorescein angiography was performed. Flare and cell values were compared with 59 normal age and sex-matched control eyes and correlated with fluorescein angiographic findings. Both aqueous flare (12.321 (SD 6.717) photon counts/ms) and aqueous cells (mean 3.37 cells/0.075 x 10(6)/l) were significantly increased in eyes with RVO in comparison with the normal control group (flare 4.288 (SD 1.144) photon counts/ms, cells 0.54 cells/0.075 x 10(6)/l, p < 0.0001 and p < 0.005). Flare values in eyes with central RVO (19.517 (SD 7.762) photon counts/ms) were significantly higher than in eyes with branch RVO (9.443 (SD 3.307) photon counts/ms, p < 0.0001). Significant correlations were found between flare values and area of RVO (r = 0.70, p < 0.0001) and between flare values and area of retinal non-perfusion (r = 0.76, p < 0.0001). There were also significant correlations between flare values and number of cotton wool spots (r = 0.54, p < 0.0002) and between cell counts and degree of cystoid macular oedema (r = 0.46, p < 0.006). Our findings show that aqueous protein concentration, as indicated by flare, and aqueous cells are increased in RVO and that changes of aqueous flare correlate with fluorescein angiographic findings that reflect the severity of RVO. Measurements with LFCM may be useful non-invasively to quantify changes of the ocular barrier functions in RVO.
使用激光闪烁细胞仪(LFCM)评估视网膜静脉阻塞(RVO)患者眼睛的血-房水屏障改变。对42例RVO患者的42只眼睛(30只分支静脉阻塞,12只中央静脉阻塞)测定房水闪光和房水细胞,并进行视网膜荧光血管造影。将闪光和细胞值与59只年龄和性别匹配的正常对照眼睛进行比较,并与荧光血管造影结果相关联。与正常对照组相比,RVO患者眼睛的房水闪光(12.321(标准差6.717)光子计数/毫秒)和房水细胞(平均3.37个细胞/0.075×10⁶/升)均显著增加(闪光4.288(标准差1.144)光子计数/毫秒,细胞0.54个细胞/0.075×10⁶/升,p<0.0001和p<0.005)。中央RVO患者眼睛的闪光值(19.517(标准差7.762)光子计数/毫秒)显著高于分支RVO患者眼睛的闪光值(9.443(标准差3.307)光子计数/毫秒,p<0.0001)。发现闪光值与RVO面积之间存在显著相关性(r = 0.70,p<0.0001),闪光值与视网膜无灌注面积之间也存在显著相关性(r = 0.76,p<0.0001)。闪光值与棉绒斑数量之间也存在显著相关性(r = 0.54,p<0.0002),细胞计数与黄斑囊样水肿程度之间也存在显著相关性(r = 0.46,p<0.006)。我们的研究结果表明,RVO患者的房水蛋白浓度(以闪光表示)和房水细胞增加,房水闪光的变化与反映RVO严重程度的荧光血管造影结果相关。使用LFCM进行测量可能有助于无创量化RVO患者眼屏障功能的变化。