Suppr超能文献

淋病奈瑟菌AccuProbe培养鉴定试验与其他快速方法的比较评估

Comparative evaluation of AccuProbe culture identification test for Neisseria gonorrhoeae and other rapid methods.

作者信息

Young H, Moyes A

机构信息

Scottish Gonococcal Reference Laboratory, Department of Medical Microbiology, Edinburgh University Medical School, Scotland.

出版信息

J Clin Microbiol. 1993 Aug;31(8):1996-9. doi: 10.1128/jcm.31.8.1996-1999.1993.

Abstract

The AccuProbe chemiluminescent culture identification test for Neisseria gonorrhoeae (Gen-Probe Inc., San Diego, Calif.) was assessed in a comparative evaluation with other rapid methods by using 269 isolates of oxidase-positive, gram-negative diplococci. Chemiluminescence was read with a PAL luminometer, and results were expressed as PAL light units (PLUs): the cutoff value for a positive identification was 1,500 PLUs. All 200 isolates of gonococci confirmed by carbohydrate utilization and serotyped with monoclonal antibodies were identified correctly by AccuProbe on initial testing. The API Quadferm system (Bio Merieux, Marcy l'Etoile, France) identified 95% (n = 190) of the gonococci correctly on initial testing and 99.5% (n = 199) on repeat testing, while the Phadebact Monoclonal GC test (Kara Bio Diagnostics AB, Huddinge, Sweden) identified 95.5% (n = 191) of the gonococci on both initial and repeat testing; 8 of the Phadebact-negative isolates were all of the same rare serovar (serovar 1B-17). The mean PLU for the gonococcal isolates was 9,014 (range 2,264 to 10,845) compared with a mean of 51 (range, 8 to 109) for the 69 nongonococcal isolates. We conclude that the AccuProbe culture confirmation test provides a rapid and accurate objective means of identifying cultured N. gonorrhoeae isolates.

摘要

采用269株氧化酶阳性的革兰氏阴性双球菌,将淋病奈瑟菌的AccuProbe化学发光培养鉴定试验(Gen - Probe公司,加利福尼亚州圣地亚哥)与其他快速方法进行了比较评估。用PAL发光计读取化学发光值,结果以PAL光单位(PLU)表示:阳性鉴定的临界值为1500 PLU。通过碳水化合物利用确认并用单克隆抗体进行血清分型的所有200株淋球菌在初次检测时均被AccuProbe正确鉴定。API Quadferm系统(法国Bio Merieux公司,马西耶图瓦勒)在初次检测时正确鉴定了95%(n = 190)的淋球菌,重复检测时正确鉴定率为99.5%(n = 199);而Phadebact单克隆GC试验(瑞典哈丁格Kara生物诊断公司)在初次和重复检测时均正确鉴定了95.5%(n = 191)的淋球菌;Phadebact阴性的8株分离株均属于同一罕见血清型(血清型1B - 17)。淋球菌分离株的平均PLU为9014(范围2264至10845),相比之下,69株非淋球菌分离株的平均PLU为51(范围8至109)。我们得出结论,AccuProbe培养确认试验为鉴定培养的淋病奈瑟菌分离株提供了一种快速、准确的客观方法。

相似文献

本文引用的文献

9
Use of nucleic acid probes for the detection of sexually transmitted infectious agents.使用核酸探针检测性传播感染病原体。
Diagn Microbiol Infect Dis. 1986 Mar;4(3 Suppl):101S-109S. doi: 10.1016/s0732-8893(86)80048-7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验