Bartlett A, Dormandy K M, Hawkey C M, Stableforth P, Voller A
Br Med J. 1976 Apr 24;1(6016):994-6. doi: 10.1136/bmj.1.6016.994.
Factor-VIII-related antigen was measured, both by an enzyme immunoassay using a microplate method and by the Laurell technique, in normal people, patients with von Willebrand's disease, haemophiliacs, and obligatory haemophilia carriers. The enzyme immunoassay was simpler to perform and gave equally reliable and reproducible results. Many more assays could be carried out at any one time.
采用微孔板酶免疫测定法和劳雷尔技术,对正常人、血管性血友病患者、血友病患者及血友病携带者测定了Ⅷ因子相关抗原。酶免疫测定法操作更简便,结果同样可靠且可重复。在同一时间内可进行更多次检测。