Suppr超能文献

用对流免疫电泳法快速检测和定量产气荚膜梭菌肠毒素

Rapid detection and quantitation of Clostridium perfringens enterostoxin by counterimmunoelectrophoresis.

作者信息

Naik H S, Duncan C L

出版信息

Appl Environ Microbiol. 1977 Aug;34(2):125-8. doi: 10.1128/aem.34.2.125-128.1977.

Abstract

Conditions for detection and quantitation of Clostridium perfringens enterotoxin by counterimmunoelectrophoresis are described. As little as 0.2 microgram of enterotoxin per ml could be detected. The test was found to be rapid, sensitive, specific and easy for the detection and quantitation of enterotoxin.

摘要

本文描述了用对流免疫电泳法检测和定量产气荚膜梭菌肠毒素的条件。每毫升低至0.2微克的肠毒素都能被检测到。该试验被发现对于肠毒素的检测和定量而言快速、灵敏、特异且简便。