Glaucoma Service, Wilmer Ophthalmological Institute, The Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Invest Ophthalmol Vis Sci. 2011 Feb 22;52(2):858-64. doi: 10.1167/iovs.10-5556.
To measure the accuracy of TonoLab (TioLat, Helsinki, Finland) tonometry in mice with spontaneous or induced experimental glaucoma.
Chronic intraocular pressure (IOP) elevation was induced in one eye of 32 mice by injection of polystyrene beads and viscoelastic material. Three to 6 weeks later, the eyes were cannulated and manometrically set to 10, 20, 30, 40, or 50 mm Hg. The mice were 8-week and 8-month-old C57BL/6, 8-week-old DBA/2J, and 8-week-old CD1. The TonoLab calibration was also tested on five aged DBA/2J mice with spontaneous glaucoma. The relation of the TonoLab reading to manometric IOP was evaluated in multivariate linear regression models with axial length, IOP history, and mouse strain as independent variables.
The slope of the relationship between TonoLab and manometric IOP in all the mice was 0.998, with an intercept of 2.3 mm Hg (adjusted R in univariate regression = 0.86). Neither the mice with bead-induced glaucoma nor those with spontaneous glaucoma (older DBA/2J mice) differed significantly from the control animals in having an excellent correlation between TonoLab and manometer IOP. Longer and wider mouse eyes had slightly higher tonometrically measured IOP, whether glaucomatous or control (multivariate regression, adjusted R(2) = 0.90, P < 0.0001). There was no difference in tonometric accuracy among the three mouse strains: CD1, C57BL/6, and DBA/2J, nor between 8-week and 8-month-old C57BL/6 mice (multivariate regression, P = 0.32).
The TonoLab accurately reflects IOP in both normal mice and in eyes of mice with experimental or spontaneous glaucoma, with no detectable effect of age.
测量 TonoLab(TioLat,芬兰赫尔辛基)眼压计在自发性或实验性青光眼小鼠中的准确性。
通过注射聚苯乙烯珠和粘性材料在 32 只小鼠的一只眼内诱导慢性眼内压(IOP)升高。3 至 6 周后,对眼睛进行套管插入并进行 10、20、30、40 或 50mmHg 的压力测量。这些小鼠为 8 周和 8 月龄的 C57BL/6、8 周龄的 DBA/2J 和 8 周龄的 CD1。还在 5 只患有自发性青光眼的老年 DBA/2J 小鼠上测试了 TonoLab 的校准。使用多元线性回归模型,以眼轴长度、IOP 史和小鼠品系为自变量,评估 TonoLab 读数与眼压计 IOP 的关系。
所有小鼠的 TonoLab 与眼压计 IOP 之间的关系斜率为 0.998,截距为 2.3mmHg(单变量回归中的调整 R2=0.86)。无论是珠粒诱导性青光眼的小鼠还是自发性青光眼(老年 DBA/2J 小鼠),它们的 TonoLab 与眼压计 IOP 之间的相关性都非常好,与对照组动物没有显著差异。较长和较宽的小鼠眼睛的眼压计测量值略高,无论是否患有青光眼(多元回归,调整 R2=0.90,P<0.0001)。三种小鼠品系(CD1、C57BL/6 和 DBA/2J)之间的眼压计准确性没有差异,8 周和 8 月龄的 C57BL/6 小鼠之间也没有差异(多元回归,P=0.32)。
TonoLab 准确反映了正常小鼠和实验性或自发性青光眼小鼠眼睛中的 IOP,并且年龄没有可检测的影响。