正常眼和 LASIK 术后眼中的视网膜杂散光和光失真现象。

Retinal straylight and light distortion phenomena in normal and post-LASIK eyes.

机构信息

Optometry Research Group, Department of Optics, University of Valencia, Dr. Moliner, 50. 46100, Burjassot, Valencia, Spain.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2011 Oct;249(10):1561-6. doi: 10.1007/s00417-010-1583-7. Epub 2011 Jan 18.

Abstract

PURPOSE

To assess the relationship between measures of light distortion and retinal straylight in normal and post-LASIK subjects.

DESIGN

Cross-sectional, non-randomized, masked observational case series

SETTING

Clinica Oftalmologica Novovision, Madrid, Spain.

METHODS

Thirty eyes from 30 healthy subjects (mean age 33.9 ± 8.3 years old; mean spherical equivalent (MSE) -2.06 ± 1.40 D) and thirty six eyes from thirty six refractive surgery patients (mean age 36.1 ± 7.7 years old; mean preop MSE -3.43 ± 2.23 D) were examined with the Starlights and the C-Quant straylightmeter in a case-control study.

RESULTS

The age of both treated and control groups was not statistically different (p > 0.05). Statistically significant differences between controls and post-LASIK eyes were found for luminous distortion index (LDI), but not for retinal straylight. Correlation analysis yielded significant correlation between retinal straylight Log(s) values and BCVA measures (r = 0.379, p = 0.002). Control subjects showed significant correlation between MSE and retinal straylight Log(s) values (r = -0.650, p < 0.001), while post-LASIK eyes showed a significant correlation between LDI and Log(s) values (r = 0.338, p = 0.044) and between Log(s) values and BCVA (r = 0.460, p = 0.005). Correlation between measures obtained by both methods was higher after LASIK than in control eyes, although values were quite scattered in any case.

CONCLUSION

Light distortion phenomena and retinal straylight measures are correlated in both normal and postsurgical eyes. Both parameters are increased in LASIK subjects compared to control non-operated subjects.

摘要

目的

评估正常眼和 LASIK 术后眼的光扭曲测量值与视网膜杂散光之间的关系。

设计

横断面、非随机、盲法观察性病例系列。

地点

西班牙马德里眼科诊所 Novovision。

方法

在一项病例对照研究中,使用 Starlights 和 C-Quant 杂散光仪对 30 名健康受试者(平均年龄 33.9 ± 8.3 岁;平均等效球镜(MSE)-2.06 ± 1.40 D)的 30 只眼和 36 名屈光手术患者(平均年龄 36.1 ± 7.7 岁;平均术前 MSE -3.43 ± 2.23 D)的 36 只眼进行了检查。

结果

两组患者的年龄无统计学差异(p > 0.05)。与对照组相比,LASIK 术后组的光扭曲指数(LDI)存在显著差异,但视网膜杂散光无显著差异。相关性分析显示,视网膜杂散光 Log(s)值与最佳矫正视力(BCVA)之间存在显著相关性(r = 0.379,p = 0.002)。对照组 MSE 与视网膜杂散光 Log(s)值之间存在显著相关性(r = -0.650,p < 0.001),而 LASIK 术后组 LDI 与 Log(s)值之间存在显著相关性(r = 0.338,p = 0.044),Log(s)值与 BCVA 之间存在显著相关性(r = 0.460,p = 0.005)。与对照组相比,LASIK 术后组两种方法获得的指标之间的相关性更高,但在任何情况下相关性都相当分散。

结论

正常眼和术后眼的光扭曲现象和视网膜杂散光测量值存在相关性。LASIK 术后患者的两种参数均高于对照组非手术患者。