OBJECTIVE

Clear depiction of the common bile duct is important when evaluating neonatal cholestasis in order to differentiate biliary atresia from other diseases. During MR cholangiopancreatography, the T2-shortening effect of gadolinium can increase the contrast-to-noise ratio (CNR) of the bile duct and enhance its depiction. The purpose of this study was to confirm, by performing a phantom study, the T2-shortening effect of gadolinium, to evaluate the effect of different gadolinium chelates with different gadolinium concentrations and different magnetic field strengths for investigating the optimal combination of these conditions, and for identifying the maximum CNR for the evaluation of the biliary system.

MATERIALS AND METHODS

MR imaging using a T2-weighted single-shot fast spin echo sequence and T2 relaxometry was performed with a sponge phantom in a syringe tube. Two kinds of contrast agents (Gd-DTPA and Gd-EOB-DTPA) with different gadolinium concentrations were evaluated with 1.5T and 3T scanners. The signal intensities, the CNRs and the T2 relaxation time were analyzed.

RESULTS

The signal intensities significantly decreased as the gadolinium concentrations increased (p < 0.001) with both contrast agents. These signal intensities were higher on a 3T (p < 0.001) scanner. The CNRs were higher on a 1.5T (p < 0.001) scanner and they showed no significant change with different gadolinium concentrations. The T2 relaxation time also showed a negative correlation with the gadolinium concentrations (p < 0.001) and the CNRs showed decrease more with Gd-EOB-DTPA (versus Gd-DTPA; p < 0.001) on a 3T scanner (versus 1.5T; p < 0.001).

CONCLUSION

A T2-shortening effect of gadolinium exhibits a negative correlation with the gadolinium concentration for both the signal intensities and the T2 relaxation time. A higher CNR can be obtained with Gd-DTPA on a 1.5T MRI scanner.

摘要

目的

在评估新生儿胆汁淤积症时,清晰显示胆总管对于区分胆道闭锁与其他疾病非常重要。在磁共振胰胆管成像(MRCP)中,钆的 T2 缩短效应可以提高胆管的对比噪声比(CNR)并增强其显示效果。本研究旨在通过体模研究来证实钆的 T2 缩短效应,评估不同浓度的不同顺磁造影剂(Gd-DTPA 和 Gd-EOB-DTPA)在不同磁场强度下的效果,以优化这些条件的组合,并确定评估胆道系统的最大 CNR。

材料与方法

使用 T2 加权单次快速自旋回波序列和 T2 弛豫测量法在注射器管中的海绵体模中进行磁共振成像。在 1.5T 和 3T 扫描仪上评估了两种具有不同浓度的造影剂(Gd-DTPA 和 Gd-EOB-DTPA)。分析了信号强度、CNR 和 T2 弛豫时间。

结果

两种造影剂的信号强度均随钆浓度的增加而显著降低(p < 0.001)。在 3T 扫描仪上信号强度更高(p < 0.001)。在 1.5T 扫描仪上 CNR 更高(p < 0.001),且与钆浓度无关。T2 弛豫时间与钆浓度呈负相关(p < 0.001),且在 3T 扫描仪上(与 1.5T 相比,p < 0.001)和 Gd-EOB-DTPA 时(与 Gd-DTPA 相比,p < 0.001),CNR 下降更为明显。

结论

钆的 T2 缩短效应与信号强度和 T2 弛豫时间的钆浓度呈负相关。在 1.5T MRI 扫描仪上,使用 Gd-DTPA 可以获得更高的 CNR。