Suppr超能文献

高效液相色谱法测定血浆丙二醛的特异性、准确性和敏感性。

A specific, accurate, and sensitive measure of total plasma malondialdehyde by HPLC.

机构信息

Faculty of Medicine and Health Sciences, University of the United Arab Emirates, Al Ain, United Arab Emirates; and.

School of Pharmacy and Life Sciences, Robert Gordon University, Schoolhill, Aberdeen, Scotland.

出版信息

J Lipid Res. 2013 Mar;54(3):852-858. doi: 10.1194/jlr.D032698. Epub 2012 Dec 20.

Abstract

Malondialdehyde (MDA) is one of the most commonly reported biomarkers of lipid peroxidation in clinical studies. The reaction of thiobarbituric acid (TBA) with MDA to yield a pink chromogen attributable to an MDA-TBA₂ adduct is a common assay approach with products being quantified by ultraviolet-Vis assay as nonspecific TBA-reactive substances (TBARS) or chromatographically as MDA. The specificity of the TBARS assay was compared with both chromatographic assays for total plasma MDA. The levels of total plasma MDA were significantly lower than the plasma TBARS in each of the samples examined, and interestingly, the interindividual variation apparent in the level of plasma MDA was not evident in the plasma TBARS assay. Each of the four online chromatographic detectors yielded a precise, sensitive, and accurate determination of total plasma MDA, and selected-ion monitoring was the most-accurate assay (101.3%, n = 4). The online diode array detectors provided good assay specificity (peak purity index of 999), sensitivity, precision, and accuracy. This research demonstrates the inaccuracy that is inherent in plasma TBARS assays, which claim to quantify MDA, and it is proposed that the TBARS approach may limit the likelihood of detecting true differences in the level of lipid peroxidation in clinical studies.

摘要

丙二醛(MDA)是临床研究中最常报道的脂质过氧化生物标志物之一。硫代巴比妥酸(TBA)与 MDA 反应生成粉红色显色剂归因于 MDA-TBA₂加合物,这是一种常用的测定方法,通过紫外可见分光光度法将产物定量为非特异性 TBA 反应物质(TBARS)或色谱法作为 MDA。TBARS 测定的特异性与总血浆 MDA 的两种色谱测定方法进行了比较。总血浆 MDA 水平明显低于每个样本中的血浆 TBARS,有趣的是,血浆 MDA 水平的个体间差异在血浆 TBARS 测定中并不明显。四种在线色谱检测器均能精确、灵敏、准确地测定总血浆 MDA,而选择离子监测法是最准确的测定法(101.3%,n=4)。在线二极管阵列检测器提供了良好的测定特异性(峰纯度指数为 999)、灵敏度、精密度和准确性。本研究证明了血浆 TBARS 测定法所固有的不准确性,该测定法声称可定量 MDA,并且建议 TBARS 方法可能会限制在临床研究中检测脂质过氧化水平真实差异的可能性。

相似文献

引用本文的文献

本文引用的文献

7
Fatty acids and oxidative stress in psychiatric disorders.精神疾病中的脂肪酸与氧化应激