表面处理对牙种植体骨结合的影响:体内组织学、组织形态计量学及放射学分析

Influence of surface treatment on osseointegration of dental implants: histological, histomorphometric and radiological analysis in vivo.

作者信息

Calvo-Guirado José Luis, Satorres-Nieto Marta, Aguilar-Salvatierra Antonio, Delgado-Ruiz Rafael Arcesio, Maté-Sánchez de Val José Eduardo, Gargallo-Albiol Jordi, Gómez-Moreno Gerardo, Romanos Georgios E

机构信息

Faculty of Medicine and Dentistry, University of Murcia, Murcia, Spain.

出版信息

Clin Oral Investig. 2015 Mar;19(2):509-17. doi: 10.1007/s00784-014-1241-2. Epub 2014 Apr 16.

Abstract

OBJECTIVE

The aim of this article is to compare the influence of surface treatment on the integration (at 2, 4 and 8 weeks) of 120 dental implants inserted in 60 tibiae of rabbits.

MATERIALS AND METHODS

Four different surfaces were double-blind tested: blasted, acid-etched and discrete crystal deposition (DCD) (group A); blasted (group B); acid-etched (group C) and blasted and acid-etched (group D). Bone-to-implant contact plus reverse torque and bone level were measured at the time of implant insertion and at 14, 28 and 56 days of healing.

RESULTS

Group A showed the highest early and late bone-to-implant contact (BIC) values: 40.8 ± 2.3 % at 14 days decreasing to 27.7 ± 1.1 % after 28 days and 39.4 ± 1.4 % at 56 days. For group B, the average BIC values at 14, 28 and 56 days were 23.34 ± 2.1, 23.77 ± 1.9 and 29.47 ± 1.7 %, respectively. Group C showed a value of 25.72 ± 2.3 % after 14 days of integration, 34.92 ± 2.2 % at 28 days and 32.91 ± 1.6 % at 56 days. Group D showed a BIC value of 32 ± 2.5 % at 14 days, 32.85 ± 1.4 % at 28 days and 34.04 ± 2.3 % at 56 days. In the scanning electron microscopy (SEM) analysis, no statistically significant differences were found. The Ca/P ratio values were 1.762 for surface A, 1.625 for surface B, 1.663 for surface C and finally 1.722 for surface D.

CONCLUSIONS

Therefore, we conclude that even if there seems to be a tendency to obtain better BIC results with surface A (blasted-etched and covered with hydroxyapatite (HA)), no statistical differences were obtained in this study.

CLINICAL RELEVANCE

The study shows the influence of different implant surfaces in increasing osseointegation for immediate loading implants.

摘要

目的

本文旨在比较表面处理对植入60只兔胫骨的120颗牙种植体(在2周、4周和8周时)骨结合的影响。

材料与方法

对四种不同表面进行双盲测试:喷砂、酸蚀和离散晶体沉积(DCD)(A组);喷砂(B组);酸蚀(C组)以及喷砂和酸蚀(D组)。在种植体植入时以及愈合14天、28天和56天时测量骨与种植体的接触情况、反向扭矩和骨水平。

结果

A组在早期和晚期均显示出最高的骨与种植体接触(BIC)值:14天时为40.8±2.3%,28天后降至27.7±1.1%,56天时为39.4±1.4%。B组在14天、28天和56天的平均BIC值分别为23.34±2.1%、23.77±1.9%和29.47±1.7%。C组在整合14天后的值为25.72±2.3%,28天时为34.92±2.2%,56天时为32.91±1.6%。D组在14天时的BIC值为32±2.5%,28天时为32.85±1.4%,56天时为34.04±2.3%。在扫描电子显微镜(SEM)分析中,未发现统计学上的显著差异。表面A的钙磷比(Ca/P)值为1.762,表面B为1.625,表面C为1.663,表面D为1.722。

结论

因此,我们得出结论,即使似乎有使用表面A(喷砂-酸蚀并覆盖羟基磷灰石(HA))获得更好BIC结果的趋势,但在本研究中未获得统计学差异。

临床意义

该研究显示了不同种植体表面对即刻负重种植体增加骨整合的影响。