Gupta Shikha, Sinha Gautam, Sharma Reetika, Nayak Bhagabat, Patil Bharat, Kashyap Bibhuti, Shameer Abdul, Dada Tanuj
Dr Rajendra Prasad Center for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, 110029, India.
Dr Rajendra Prasad Center for Ophthalmic Sciences, All India Institute of Medical Sciences, Room No: 376, New Delhi, 110029, India.
Int Ophthalmol. 2016 Feb;36(1):9-15. doi: 10.1007/s10792-015-0067-5. Epub 2015 Mar 28.
To estimate agreement in diurnal variations of intraocular pressure (IOP) by Tono-Pen (TP) and Goldmann applanation tonometer (GAT) in glaucoma patients on topical anti-glaucoma medication(s). IOP was measured at every 3 h from 7 a.m. to 10 a.m. in 50 eyes of glaucoma patients on topical medication(s). Diurnal fluctuation of IOP by each method was calculated as maximum-minimum IOP in a day. Central corneal thickness (CCT) was measured by ultrasonic pachymeter. There was good correlation between TP and GAT at all times during a day, minimum, and maximum IOPs during a day (Correlation coefficient, 0.706 at 7 a.m., 0.624 at 10 a.m., 0.682 at 1 p.m., 0.814 at 4 p.m., 0.652 at 7 p.m., 0.572 at 10 p.m., 0.668 minimum IOP, 0.689 maximum IOP). Mean IOPs by TP were always higher than GAT at all times during a day. Bland-Altman plots suggested a close relationship between the two sets of readings, and that this relationship was consistent at different times in a day, in maximum IOPs, minimum IOPs and also in fluctuation of IOPs. Linear regression analysis between the differences of diurnal fluctuation (diurnal fluctuation by GAT-diurnal fluctuation by TP) and CCT showed strong association (R 2 = 0.857, p < 0.001). The mean change in difference of diurnal fluctuation (GAT-TP) for a 10-micron increase in CCT was 0.69 mmHg. TP can be considered a reliable alternative to GAT in glaucoma patients for knowing the diurnal control of IOP; however these two methods should not be used interchangeably. Difference of diurnal fluctuation between two methods is dependent on CCT.
评估在使用局部抗青光眼药物治疗的青光眼患者中,非接触眼压计(Tono-Pen,TP)和Goldmann压平眼压计(GAT)测量眼压昼夜变化的一致性。对50只使用局部药物治疗的青光眼患者的眼睛,于上午7点至10点每3小时测量一次眼压。每种方法测量的眼压昼夜波动计算为一天中的最高眼压减去最低眼压。使用超声角膜测厚仪测量中央角膜厚度(CCT)。一天中所有时间点、一天中的最低眼压和最高眼压时,TP与GAT之间均具有良好的相关性(相关系数:上午7点为0.706,上午10点为0.624,下午1点为0.682,下午4点为0.814,晚上7点为0.652,晚上10点为0.572,最低眼压时为0.668,最高眼压时为0.689)。一天中所有时间点,TP测量的平均眼压均始终高于GAT测量的平均眼压。Bland-Altman图表明两组读数之间关系密切,且这种关系在一天中的不同时间、最高眼压、最低眼压以及眼压波动情况中均保持一致。昼夜波动差值(GAT测量的昼夜波动 - TP测量的昼夜波动)与CCT之间的线性回归分析显示出强相关性(R² = 0.857,p < 0.001)。CCT每增加10微米,昼夜波动差值(GAT - TP)的平均变化为0.69 mmHg。对于了解青光眼患者眼压的昼夜控制情况,TP可被视为GAT的可靠替代方法;然而,这两种方法不应互换使用。两种方法的昼夜波动差值取决于CCT。