Suppr超能文献

即使在正常观察者中,明视觉和中间视觉对比敏感度也存在明显分离。

Marked dissociation of photopic and mesopic contrast sensitivity even in normal observers.

作者信息

Hertenstein Hannah, Bach Michael, Gross Nikolai Johannes, Beisse Flemming

机构信息

Eye Center, University of Freiburg, Freiburg, Germany.

Ophthalmology Department, University of Heidelberg, Heidelberg, Germany.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2016 Feb;254(2):373-84. doi: 10.1007/s00417-015-3020-4. Epub 2015 Apr 29.

Abstract

AIM

Although contrast vision is not routinely tested, it is important: for instance, it predicts traffic incidents better than visual acuity. Mesopic contrast sensitivity (CS) testing approximates low-lighting conditions but entails dark adaptation, which can disrupt clinical routine. In receptor-specific diseases, a dissociation of photopic and mesopic sensitivity would be expected, but can photopic CS act as a surrogate measure for mesopic CS, at least for screening purposes?

METHODS

Photopic and mesopic contrast sensitivities were studied in three groups: 47 normal subjects, 23 subjects with glaucoma, and three subjects with cataract. Twenty-eight of the normal subjects were additionally tested with artificial blur. Photopic contrast sensitivity was assessed with both the Freiburg Acuity and Contrast Test (FrACT) and the Mars Letter Contrast Sensitivity Charts. Mesopic contrast sensitivity, without and with glare, was measured with the Mesoptometer IIb. Coefficients of repeatability and limits of agreement were calculated for all tests.

RESULTS

Test-retest limits of agreement were ± 0.17 logCS for Mars, ± 0.21 logCS for FrACT, and ±0.20 logCS / ± 0.14 logCS for Mesoptometer IIb without and with glare, respectively. In terms of inter-test comparison, Mars and FrACT largely agreed, except for ceiling effects in the Mars test. While mesopic and photopic contrast sensitivities correlate significantly (r  = 0.51, p < 0.01), only 27 % of the variance is in common. In particular, subjects with high photopic results may be nearly as likely to have low as well as high mesopic results.

CONCLUSIONS

The photopic contrast sensitivity tests assessed here cannot serve as surrogate measures for current mesopic contrast sensitivity tests. Low photopic CS predicts low mesopic CS, but with normal photopic CS, mesopic CS can be normal or pathologic.

摘要

目的

尽管对比视觉并非常规检测项目,但它很重要:例如,它比视力能更好地预测交通事故。中间视觉对比敏感度(CS)测试可模拟低光照条件,但需要暗适应,这可能会干扰临床常规操作。在受体特异性疾病中,明视觉和中间视觉敏感度预计会出现分离,但明视觉CS能否作为中间视觉CS的替代指标,至少用于筛查目的呢?

方法

对三组人群的明视觉和中间视觉对比敏感度进行了研究:47名正常受试者、23名青光眼患者和3名白内障患者。另外对28名正常受试者进行了人工模糊测试。使用弗赖堡视力与对比测试(FrACT)和火星字母对比敏感度图表评估明视觉对比敏感度。使用Mesoptometer IIb测量有无眩光情况下的中间视觉对比敏感度。计算所有测试的重复性系数和一致性界限。

结果

火星测试的重测一致性界限为±0.17 logCS,FrACT为±0.21 logCS,Mesoptometer IIb在无眩光和有眩光情况下分别为±0.20 logCS / ±0.14 logCS。在测试间比较方面,火星测试和FrACT基本一致,除了火星测试中的天花板效应。虽然中间视觉和明视觉对比敏感度显著相关(r = 0.51,p < 0.01),但只有27%的方差是共同的。特别是,明视觉结果高的受试者中间视觉结果可能同样有高有低。

结论

此处评估的明视觉对比敏感度测试不能作为当前中间视觉对比敏感度测试的替代指标。低明视觉CS预示着低中间视觉CS,但明视觉CS正常时,中间视觉CS可能正常也可能异常。