Spontaneous venous pulsation correlates negatively with elevated intracranial pressure and papilledema, and it relates to glaucoma. Yet, its etiology remains unclear. A key element to elucidate its underlying mechanism is the time at which collapse occurs with respect to the heart cycle, but previous reports are contradictory. We assessed this question in healthy subjects using quantitative measurements of both vein diameters and artery lateral displacements; the latter being used as the marker of the ocular systole time.
We recorded 5-second fundus sequences with a near-infrared scanning laser ophthalmoscope in 12 young healthy subjects. The image sequences were coregistered, cleaned from microsaccades, and filtered via a principal component analysis to remove nonpulsatile dynamic features. Time courses of arterial lateral displacement and of diameter at sites of spontaneous venous pulsation or proximal to the disk were retrieved from those image sequences and compared.
Four subjects displayed both arterial and venous pulsatile waveforms. On those, we observed venous diameter waveforms differing markedly among the subjects, ranging from a waveform matching the typical intraocular pressure waveform to a close replica of the arterial waveform.
The heterogeneity in waveforms and arteriovenous phases suggests that the mechanism governing the venous outflow resistance differs among healthy subjects.
Further characterizations are necessary to understand the heterogeneous mechanisms governing the venous outflow resistance as this resistance is altered in glaucoma and is instrumental when monitoring intracranial hypertension based on fundus observations.
自发性静脉搏动与颅内压升高和视乳头水肿呈负相关,且与青光眼有关。然而,其病因仍不清楚。阐明其潜在机制的一个关键因素是静脉塌陷相对于心动周期发生的时间,但先前的报道相互矛盾。我们在健康受试者中使用静脉直径和动脉侧向位移的定量测量来评估这个问题;后者用作眼收缩期时间的标志物。
我们用近红外扫描激光检眼镜记录了12名年轻健康受试者的5秒眼底序列。对图像序列进行配准、去除微扫视,并通过主成分分析进行滤波,以去除非搏动性动态特征。从这些图像序列中获取动脉侧向位移和自发性静脉搏动部位或视盘近端直径的时间进程并进行比较。
4名受试者同时显示出动脉和静脉搏动波形。在这些受试者中,我们观察到静脉直径波形在不同受试者之间有明显差异,范围从与典型眼内压波形匹配的波形到动脉波形的紧密复制品。
波形和动静脉相位的异质性表明,健康受试者中控制静脉流出阻力的机制不同。
有必要进一步表征控制静脉流出阻力的异质机制,因为这种阻力在青光眼中会发生改变,并且在基于眼底观察监测颅内高压时很重要。