Suppr超能文献

兔暗视全视野视网膜电图的重测信度

Test-retest reliability of scotopic full-field electroretinograms in rabbits.

作者信息

Luebke Jan, Anton Alexandra, Bach Michael

机构信息

Eye Center, Medical Center, University of Freiburg, Killianstrasse 5, 79106, Freiburg, Germany.

Faculty of Medicine, University of Freiburg, Freiburg, Germany.

出版信息

Doc Ophthalmol. 2017 Jun;134(3):157-165. doi: 10.1007/s10633-017-9582-1. Epub 2017 Mar 16.

Abstract

PURPOSE

To explore test-retest reliability of standard scotopic full-field ERG measurements in New Zealand White rabbits. The ERG is widely used for testing of retinal integrity after any ocular treatment. We here present detailed stimulus-response dependencies for single healthy and untreated animals, concentrating on test-retest reproducibility.

MATERIALS AND METHODS

Five New Zealand White rabbits (aged 8-10 weeks, weight about 2.0-2.5 kg) underwent binocular ERG measurements after intramuscular anesthesia and pharmaceutical pupillary dilatation at a baseline day and 10 days later. Eleven scotopic flash strengths (0.0001-10 cd s/m) were presented. Variability was quantified via the 95% limits of agreement (LOA).

RESULTS

The a-waves displayed the typical monotonic sigmoid amplitude increase with flash strength, and the b-waves peaked at 0.01 cd s/m, followed by a marked dip at 0.1-0.3 cd s/m. LOA of both waves went through a maximum in the dip region. LOA divided by mean amplitudes (relative LOA) was fairly flat over flash strength, around 20% beyond the dip. Intraindividual interocular variability was markedly lower, around 10%.

CONCLUSIONS

Scotopic ERG responses in rabbits display a region of high variability at 0.1-0.3 cd s/m; beyond that region the amplitude-LOA is 20%, the interocular LOA being half that value. The use of intraindividual control eyes for testing any toxicity of ocular agents thus appears markedly more sensitive. As a rule of thumb, we found the relative 95% LOA as 33% between individuals, 20% across sessions and 10% between eyes.

摘要

目的

探讨新西兰白兔标准暗视全视野视网膜电图(ERG)测量的重测信度。ERG被广泛用于任何眼部治疗后视网膜完整性的检测。我们在此展示了单个健康未治疗动物详细的刺激-反应依赖性,重点关注重测的可重复性。

材料与方法

五只新西兰白兔(8 - 10周龄,体重约2.0 - 2.5千克)在基线日及10天后,经肌肉麻醉和药物性瞳孔散大后进行双眼ERG测量。呈现了11种暗视闪光强度(0.0001 - 10 cd·s/m²)。通过95%一致性界限(LOA)对变异性进行量化。

结果

a波随闪光强度呈现典型的单调S形振幅增加,b波在0.01 cd·s/m²时达到峰值,随后在0.1 - 0.3 cd·s/m²处出现明显下降。两个波的LOA在下降区域达到最大值。LOA除以平均振幅(相对LOA)在闪光强度范围内相当平稳,在下降区域之外约为20%。个体内眼间变异性明显更低,约为10%。

结论

兔的暗视ERG反应在0.1 - 0.3 cd·s/m²区域显示出高变异性;在该区域之外,振幅-LOA为20%,眼间LOA为该值的一半。因此,使用个体内对照眼来检测眼用药物的任何毒性似乎明显更敏感。根据经验,我们发现个体间相对95% LOA为33%,不同测量时段间为20%,眼间为10%。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验