Suppr超能文献

正畸用钢丝与金合金舌侧托槽的电偶耦合:腐蚀是一个问题吗?

Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires: Is corrosion a concern?

出版信息

Angle Orthod. 2018 Jul;88(4):450-457. doi: 10.2319/092917-655.1. Epub 2018 Mar 6.

Abstract

OBJECTIVES

The aim of this research was to assess galvanic behavior of lingual orthodontic brackets coupled with representative types of orthodontic wires.

MATERIALS AND METHODS

Three types of lingual brackets: Incognito (INC), In-Ovation L (IOV), and STb (STB) were combined with a stainless steel (SS) and a nickel-titanium (NiTi) orthodontic archwire. All materials were initially investigated by scanning electron microscopy / x-ray energy dispersive spectroscopy (SEM/EDX) while wires were also tested by x-ray diffraction spectroscopy (XRD). All bracket-wire combinations were immersed in acidic 0.1M NaCl 0.1M lactic acid and neutral NaF 0.3% (wt) electrolyte, and the potential differences were continuously recorded for 48 hours.

RESULTS

The SEM/EDX analysis revealed that INC is a single-unit bracket made of a high gold (Au) alloy while IOV and STB are two-piece appliances in which the base and wing are made of SS alloys. The SS wire demonstrated austenite and martensite iron phase, while NiTi wire illustrated an intense austenite crystallographic structure with limited martensite. All bracket wire combinations showed potential differences below the threshold of galvanic corrosion (200 mV) except for INC and STB coupled with NiTi wire in NaF media.

CONCLUSIONS

The electrochemical results indicate that all brackets tested demonstrated galvanic compatibility with SS wire, but fluoride treatment should be used cautiously with NiTi wires coupled with Au and SS brackets.

摘要

目的

本研究旨在评估舌侧正畸托槽与代表性类型正畸丝的电偶行为。

材料与方法

将三种类型的舌侧托槽(Incognito[INC]、In-Ovation L[IOV]和 STb[STB])与不锈钢(SS)和镍钛(NiTi)正畸弓丝组合。所有材料均通过扫描电子显微镜/ X 射线能量色散光谱(SEM/EDX)进行初步研究,而弓丝也通过 X 射线衍射光谱(XRD)进行测试。所有托槽-弓丝组合均浸入酸性 0.1M NaCl 0.1M 乳酸和中性 NaF 0.3%(wt)电解质中,并连续记录 48 小时的电位差。

结果

SEM/EDX 分析表明,INC 是一种由高金(Au)合金制成的单单元托槽,而 IOV 和 STB 是由 SS 合金制成的两件式器械,其中底座和翼由 SS 合金制成。SS 丝显示出奥氏体和马氏体铁相,而 NiTi 丝则显示出强烈的奥氏体晶体结构,马氏体相有限。除了在 NaF 介质中与 NiTi 丝结合的 INC 和 STB 之外,所有托槽-弓丝组合的电位差均低于电偶腐蚀的阈值(200 mV)。

结论

电化学结果表明,所有测试的托槽均与 SS 丝表现出电偶相容性,但在 Au 和 SS 托槽与 NiTi 丝结合时应谨慎使用氟化物处理。

相似文献

1
Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires: Is corrosion a concern?
Angle Orthod. 2018 Jul;88(4):450-457. doi: 10.2319/092917-655.1. Epub 2018 Mar 6.
4
Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys.
Angle Orthod. 2006 Jul;76(4):705-11. doi: 10.1043/0003-3219(2006)076[0705:GCBOOA]2.0.CO;2.
5
Metallurgical characterization, galvanic corrosion, and ionic release of orthodontic brackets coupled with Ni-Ti archwires.
J Biomed Mater Res B Appl Biomater. 2007 Apr;81(1):126-34. doi: 10.1002/jbm.b.30645.
6
Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys.
Am J Orthod Dentofacial Orthop. 1990 Aug;98(2):117-26. doi: 10.1016/0889-5406(90)70005-W.
9
Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash.
J Dent Res Dent Clin Dent Prospects. 2015 Summer;9(3):159-65. doi: 10.15171/joddd.2015.030. Epub 2015 Sep 16.
10
Galvanic corrosion between orthodontic wires and brackets in fluoride mouthwashes.
Eur J Orthod. 2006 Jun;28(3):298-304. doi: 10.1093/ejo/cji102. Epub 2006 Jan 20.

引用本文的文献

3
Minimization of Adverse Effects Associated with Dental Alloys.
Materials (Basel). 2022 Oct 25;15(21):7476. doi: 10.3390/ma15217476.
4
Corrosion Behavior and In Vitro Cytotoxicity of Ni-Ti and Stainless Steel Arch Wires Exposed to Lysozyme, Ovalbumin, and Bovine Serum Albumin.
ACS Omega. 2020 Jul 24;5(30):18995-19003. doi: 10.1021/acsomega.0c02312. eCollection 2020 Aug 4.

本文引用的文献

2
Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash.
J Dent Res Dent Clin Dent Prospects. 2015 Summer;9(3):159-65. doi: 10.15171/joddd.2015.030. Epub 2015 Sep 16.
4
Microstructural and mechanical characterization of contemporary lingual orthodontic brackets.
Eur J Orthod. 2014 Aug;36(4):389-93. doi: 10.1093/ejo/cjt086. Epub 2013 Nov 14.
6
Comparison of adverse effects between lingual and labial orthodontic treatment.
Angle Orthod. 2013 Nov;83(6):1066-73. doi: 10.2319/010113-2.1. Epub 2013 Apr 12.
7
Release of metal ions from orthodontic appliances: an in vitro study.
Biol Trace Elem Res. 2012 May;146(2):272-80. doi: 10.1007/s12011-011-9233-4. Epub 2011 Oct 20.
8
Exposure to metals from orthodontic appliances by hair mineral analysis.
Environ Toxicol Pharmacol. 2011 Jul;32(1):10-6. doi: 10.1016/j.etap.2011.02.009. Epub 2011 Mar 22.
9
Galvanic corrosion between various combinations of orthodontic brackets and archwires.
Am J Orthod Dentofacial Orthop. 2011 Jul;140(1):25-31. doi: 10.1016/j.ajodo.2010.05.021.
10
Comparison of oral impacts experienced by patients treated with labial or customized lingual fixed orthodontic appliances.
Am J Orthod Dentofacial Orthop. 2011 Jun;139(6):784-90. doi: 10.1016/j.ajodo.2009.07.027.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验