Xue Chao, Xiang Yaoqi, Shen Min, Wu Di, Wang Yan
Clinical College of Ophthalmology, Tianjin Medical University, Tianjin Eye Hospital, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin, China.
School of Mechanical Engineering, Tianjin University, Tianjin, China.
J Ophthalmol. 2018 Oct 17;2018:5392041. doi: 10.1155/2018/5392041. eCollection 2018.
To investigate the anisotropic characteristics of the normal human corneal stroma using fresh corneal tissue.
Sixty-four corneal specimens extracted from stromal lenticules were included in this study. The specimens were cut in the temporal-nasal (horizontal) or superior-inferior (vertical) direction. Strip specimens were subjected to uniaxial tensile testing. The tensile properties of the specimens were measured and compared in the two directions.
The low-strain tangent modulus was statistically significantly greater in the vertical direction than in the horizontal direction (1.32 ± 0.50 MPa vs 1.17 ± 0.43 MPa; =0.035), as was the high-strain tangent modulus (51.26 ± 8.23 MPa vs 43.59 ± 7.96 MPa; ≤ 0.001). The elastic modulus in the vertical direction was also higher than that in horizontal direction at stresses of 0.01, 0.02, and 0.03 MPa, but not statistically significant; so, =0.338, 0.373, and 0.417, respectively.
The biomechanical behavior in normal human corneal stroma tissue is slightly stiffer in the vertical direction than in the horizontal direction. This information may aid our understanding of the biomechanical properties of the cornea and related diseases.
使用新鲜角膜组织研究正常人角膜基质的各向异性特征。
本研究纳入了从基质透镜状组织中提取的64个角膜标本。标本沿颞侧 - 鼻侧(水平)或上方 - 下方(垂直)方向切割。将条带状标本进行单轴拉伸试验。在两个方向上测量并比较标本的拉伸特性。
垂直方向的低应变切线模量在统计学上显著高于水平方向(1.32±0.50MPa对1.17±0.43MPa;P = 0.035),高应变切线模量也是如此(51.26±8.23MPa对43.59±7.96MPa;P≤0.001)。在0.01、0.02和0.03MPa应力下,垂直方向的弹性模量也高于水平方向,但无统计学意义;P分别为0.338、0.373和0.417。
正常人角膜基质组织的生物力学行为在垂直方向上比水平方向略硬。这些信息可能有助于我们理解角膜的生物力学特性及相关疾病。