J Biomed Opt. 2019 Mar;24(3):1-5. doi: 10.1117/1.JBO.24.3.035003.
The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In addition to the hemoglobin solution, which has a Soret band about 420 nm and two Q-bands between 500 and 600 nm, the measurements of other samples are the normal dispersion curve. The results are approximated by the Cauchy equation and Sellmeier equation, and the correlation coefficients are more than 0.997.