Ozanne G, Fauvel M
Laboratoire de sante publique du Quebec, Canada.
J Clin Microbiol. 1988 Aug;26(8):1496-500. doi: 10.1128/jcm.26.8.1496-1500.1988.
Anti-human immunodeficiency virus enzyme-linked immunosorbent assay kits marketed by Electro-Nucleonics Inc. (ENI), Genetic Systems Corp. (GSC), Organon Teknika Inc. (OTI), Ortho Diagnostic Systems Inc. (ODSI), and Wellcome Diagnostics (WD) were evaluated by using 289 randomly selected serum samples from a high-risk population and 53 serum samples likely to produce false-positive results. The radioimmunoprecipitation assay was used as the reference test. Sensitivities ranged from 96.51% (ODSI, WD) to 97.67% (ENI, GSC, OTI). Sera showing antibodies to viral glycoproteins only produced the false-negative results. Specificities ranged from 99.6% (ENI, GSC, ODSI, OTI) to 100% (WD). False-positive results were obtained with sera from patients with autoimmune disease or Epstein-Barr virus infection. Only results from GSC and OTI kits were distributed in two compact clusters well segregated on either side of the cutoff point. ODSI and GSC kits had the best intralot reproducibility. The GSC kit had the best interlot reproducibility. Cutoff values for ODSI and GSC kits were the least variable. Intraplate repeatability was good for all kits. Sample localization was not an important source of variability. Our results do not point out one outstanding kit among the five evaluated. However, the GSC kit showed the best overall results.
使用从高危人群中随机选取的289份血清样本以及53份可能产生假阳性结果的血清样本,对由电子核子学公司(ENI)、遗传系统公司(GSC)、欧加农泰尼克公司(OTI)、奥索诊断系统公司(ODSI)和威康诊断公司(WD)销售的抗人类免疫缺陷病毒酶联免疫吸附测定试剂盒进行了评估。放射免疫沉淀测定用作参考测试。灵敏度范围为96.51%(ODSI、WD)至97.67%(ENI、GSC、OTI)。仅显示针对病毒糖蛋白抗体的血清产生假阴性结果。特异性范围为99.6%(ENI、GSC、ODSI、OTI)至100%(WD)。自身免疫性疾病或爱泼斯坦-巴尔病毒感染患者的血清出现假阳性结果。只有GSC和OTI试剂盒的结果分布在截止点两侧很好分离的两个紧密簇中。ODSI和GSC试剂盒具有最佳的批内重复性。GSC试剂盒具有最佳的批间重复性。ODSI和GSC试剂盒的截止值变化最小。所有试剂盒的板内重复性良好。样本定位不是变异性的重要来源。我们的结果并未指出在评估的五种试剂盒中有一个特别突出的试剂盒。然而,GSC试剂盒显示出最佳的总体结果。