Suppr超能文献

用于心肌动脉自旋标记的改进型速度选择性标记脉冲。

Improved velocity-selective labeling pulses for myocardial ASL.

作者信息

Landes Vanessa, Javed Ahsan, Jao Terrence, Qin Qin, Nayak Krishna

机构信息

Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angles, CA, USA.

Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angles, CA, USA.

出版信息

Magn Reson Med. 2020 Oct;84(4):1909-1918. doi: 10.1002/mrm.28253. Epub 2020 Mar 15.

Abstract

PURPOSE

To develop and evaluate an improved velocity-selective (VS) labeling pulse for myocardial arterial spin labeling (ASL) perfusion imaging that addresses two limitations of current pulses: (1) spurious labeling of moving myocardium and (2) low labeling efficiency.

METHODS

The proposed myocardial VSASL labeling pulse is designed using a Fourier Transform based Velocity-Selective labeling pulse train. The pulse utilizes bipolar velocity-encoding gradients, a 9-tap velocity-encoding envelope, and double-refocusing pulses with Malcolm Levitt phase cycling. Amplitudes of the velocity-encoding envelope were optimized to minimize the labeling of myocardial velocities during stable diastole (±2-3 cm/s) and maximize the labeling of coronary velocities (10-130 cm/s during rest/stress or 10-70 cm/s during rest). Myocardial ASL experiments were performed in seven healthy subjects using the previously developed VS-ASL protocol by Jao et al with the two proposed VS pulses and original VS pulse. Myocardial ASL experiments were also performed using FAIR ASL. Myocardial perfusion and physiological noise (PN) were evaluated and compared.

RESULTS

Bloch simulations of the first and second proposed pulses show <2% labeling over ±3 cm/s and ±2 cm/s, respectively. Bloch simulations also show the mean labeling efficiency of arterial blood is 1.23 over the relevant coronary arterial ranges. In-vivo VSASL experiments show the proposed pulses provided comparable measurements to FAIR ASL and reduced TSNR in 5 of 7 subjects compared to the original VS pulse.

CONCLUSION

We demonstrate an improved VS labeling pulse specifically for myocardial ASL perfusion imaging to reduce spurious labeling of moving myocardium and PN.

摘要

目的

开发并评估一种改进的速度选择(VS)标记脉冲,用于心肌动脉自旋标记(ASL)灌注成像,以解决当前脉冲的两个局限性:(1)运动心肌的伪标记;(2)标记效率低。

方法

所提出的心肌VSASL标记脉冲采用基于傅里叶变换的速度选择标记脉冲序列进行设计。该脉冲利用双极速度编码梯度、9抽头速度编码包络以及带有马尔科姆·莱维特相位循环的双重聚焦脉冲。对速度编码包络的幅度进行优化,以尽量减少舒张期稳定状态下(±2 - 3 cm/s)心肌速度的标记,并使冠状动脉速度的标记最大化(静息/应激时为10 - 130 cm/s,静息时为10 - 70 cm/s)。在7名健康受试者中使用Jao等人先前开发的VS - ASL方案,采用两种所提出的VS脉冲和原始VS脉冲进行心肌ASL实验。还使用FAIR ASL进行心肌ASL实验。对心肌灌注和生理噪声(PN)进行评估和比较。

结果

对所提出的第一个和第二个脉冲的布洛赫模拟显示,在±3 cm/s和±2 cm/s以上的标记分别<2%。布洛赫模拟还显示,在相关冠状动脉范围内,动脉血的平均标记效率为1.23。体内VSASL实验表明,与原始VS脉冲相比,所提出的脉冲在7名受试者中的5名中提供了与FAIR ASL相当的测量结果,并降低了TSNR。

结论

我们展示了一种专门用于心肌ASL灌注成像的改进型VS标记脉冲,以减少运动心肌的伪标记和PN。

相似文献

7
Velocity-selective-inversion prepared arterial spin labeling.速度选择反转准备的动脉自旋标记
Magn Reson Med. 2016 Oct;76(4):1136-48. doi: 10.1002/mrm.26010. Epub 2015 Oct 28.

引用本文的文献

7
Velocity-selective excitation: Principles and applications.速度选择激发:原理与应用。
NMR Biomed. 2023 Feb;36(2):e4820. doi: 10.1002/nbm.4820. Epub 2022 Sep 9.

本文引用的文献

4
Design strategies for improved velocity-selective pulse sequences.用于改进速度选择脉冲序列的设计策略。
Magn Reson Imaging. 2017 Dec;44:146-156. doi: 10.1016/j.mri.2017.09.006. Epub 2017 Sep 7.
5
Velocity-selective-inversion prepared arterial spin labeling.速度选择反转准备的动脉自旋标记
Magn Reson Med. 2016 Oct;76(4):1136-48. doi: 10.1002/mrm.26010. Epub 2015 Oct 28.