Abstract

AIMS/INTRODUCTION: To prevent diabetic complications, strict glucose control and frequent monitoring of blood glucose levels with invasive methods are necessary. We considered the monitoring of tear glucose levels might be a possible method for non-invasive glucose monitoring. To develop tear glucose monitoring for clinical application, we investigated the precise correlation between the blood and tear glucose concentrations.

MATERIALS AND METHODS

A total of 10 participants and 20 participants with diabetes were admitted, and blood and tear samples were collected. Before statistical analysis, we eliminated tear samples contaminated with blood. We observed the daily blood and tear glucose dynamics, and carried out a random intercept model analysis to examine the association between the blood and tear glucose concentrations.

RESULTS

Tear occult blood tests showed that the tear glucose concentrations and their variation increased in both participants with and without diabetes as contamination of blood increased. In both participants with and without diabetes, fluctuations of the plasma glucose concentrations were observed depending on the timing of collection of the samples, and the dynamics of the tear glucose concentrations paralleled those of the plasma glucose concentrations. The random intercept model analysis showed a significant association between the plasma and tear glucose concentrations in participants with diabetes (P < 0.001). This association still existed even after adjusting for the glycated hemoglobin levels and the prandial state (P < 0.001).

CONCLUSIONS

It is important to eliminate the tear samples contaminated with blood. Tear glucose monitoring might be a reliable and non-invasive substitute method for monitoring the blood glucose concentrations for diabetes patients, irrespective of glycated hemoglobin levels and timing of sample collection.

摘要

目的/引言:为了预防糖尿病并发症,需要严格控制血糖并通过有创方法频繁监测血糖水平。我们认为监测泪液中的葡萄糖水平可能是一种非侵入性血糖监测方法。为了将泪液监测应用于临床,我们研究了血液和泪液葡萄糖浓度之间的精确相关性。

材料与方法

共纳入 10 名健康志愿者和 20 名糖尿病患者,采集血液和泪液样本。在进行统计分析之前,我们排除了受血液污染的泪液样本。我们观察了每日血液和泪液葡萄糖的动态变化,并进行随机截距模型分析,以检验血液和泪液葡萄糖浓度之间的相关性。

结果

泪液潜血检测显示,随着血液污染的增加,糖尿病患者和非糖尿病患者的泪液葡萄糖浓度及其变化均增加。在糖尿病患者和非糖尿病患者中,根据样本采集时间的不同,血浆葡萄糖浓度波动,泪液葡萄糖浓度的动态变化与血浆葡萄糖浓度平行。随机截距模型分析显示,糖尿病患者的血浆和泪液葡萄糖浓度之间存在显著相关性(P<0.001)。即使在调整糖化血红蛋白水平和进食状态后,这种相关性仍然存在(P<0.001)。

结论

重要的是要排除受血液污染的泪液样本。对于糖尿病患者,无论糖化血红蛋白水平和样本采集时间如何,泪液葡萄糖监测可能是一种可靠且非侵入性的替代方法来监测血糖浓度。