PURPOSE

The purpose of this study was to investigate and compare the prevalence and clinical characteristics of epiretinal membrane (ERM) in patients with pseudoexfoliation glaucoma (PXG) and primary open-angle glaucoma (POAG).

METHODS

In this retrospective observational study, 211 PXG eyes, 210 age-matched normal eyes, and 220 POAG eyes were included. The presence and staging of ERM (stage 1, 2, and 3 or greater) were independently assessed by 2 observers. Univariate and multivariate linear regression analyses were performed to assess the factors associated with visual field (VF) mean deviation (MD) in PXG eyes.

RESULTS

Among 211 PXG eyes, 40 (19.0%) had an ERM, while 4.1% of POAG and 2.4% of normal eyes had an ERM (P<0.001). Retinal nerve fiber layer thickness (69.4 vs. 70.4 μm, P=0.477) and VF MD (-7.7 vs. -10.4 dB, P=0.098) were not different between POAG and PXG eyes but macular thickness was greater (259.5 vs. 271.5 μm, P=0.006) in PXG eyes than in POAG. Both lower retinal nerve fiber layer thickness (β=0.337, P<0.001) and the presence of an ERM (β=-4.246, P=0.002) were independently associated with worse VF MD in PXG eyes.

CONCLUSIONS

The prevalence of ERM was significantly greater in PXG eyes than in age-matched normal or POAG eyes. The presence of ERM affected VF in PXG eyes.

摘要

目的

本研究旨在调查和比较假性剥脱综合征(PXG)和原发性开角型青光眼(POAG)患者中视网膜内表面膜(ERM)的患病率和临床特征。

方法

在这项回顾性观察研究中,纳入了 211 只 PXG 眼、210 只年龄匹配的正常眼和 220 只 POAG 眼。两名观察者独立评估 ERM(1 期、2 期和 3 期或更高级别)的存在和分期。进行单变量和多变量线性回归分析,以评估与 PXG 眼视野(VF)平均偏差(MD)相关的因素。

结果

在 211 只 PXG 眼中,40 只(19.0%)患有 ERM,而 POAG 眼中有 4.1%,正常眼中有 2.4%患有 ERM(P<0.001)。视网膜神经纤维层厚度(69.4μm 与 70.4μm,P=0.477)和 VF MD(-7.7dB 与-10.4dB,P=0.098)在 POAG 眼和 PXG 眼中没有差异,但 PXG 眼中的黄斑厚度更大(259.5μm 与 271.5μm,P=0.006)。较低的视网膜神经纤维层厚度(β=0.337,P<0.001)和 ERM 的存在(β=-4.246,P=0.002)均与 PXG 眼中更差的 VF MD 独立相关。

结论

PXG 眼中 ERM 的患病率明显高于年龄匹配的正常眼或 POAG 眼。ERM 的存在影响 PXG 眼中的 VF。